This is the description of the TCP/IP protocol for the Current25 Bricklet. General information and technical specifications for the Current25 Bricklet are summarized in its hardware description.
A general description of the TCP/IP protocol structure can be found here.
BrickletCurrent25.
get_current
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the current of the sensor.
If you want to get the current periodically, it is recommended to use the
CALLBACK_CURRENT
callback and set the period with
set_current_callback_period
.
BrickletCurrent25.
calibrate
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Calibrates the 0 value of the sensor. You have to call this function when there is no current present.
The zero point of the current sensor is depending on the exact properties of the analog-to-digital converter, the length of the Bricklet cable and the temperature. Thus, if you change the Brick or the environment in which the Bricklet is used, you might have to recalibrate.
The resulting calibration will be saved on the EEPROM of the Current Bricklet.
BrickletCurrent25.
is_over_current
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns true if more than 25A were measured.
Note
To reset this value you have to power cycle the Bricklet.
BrickletCurrent25.
get_analog_value
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the value as read by a 12-bit analog-to-digital converter.
Note
The value returned by get_current
is averaged over several samples
to yield less noise, while get_analog_value
gives back raw
unfiltered analog values. The only reason to use get_analog_value
is,
if you need the full resolution of the analog-to-digital converter.
If you want the analog value periodically, it is recommended to use the
CALLBACK_ANALOG_VALUE
callback and set the period with
set_analog_value_callback_period
.
BrickletCurrent25.
get_identity
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here.
BrickletCurrent25.
set_current_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the CALLBACK_CURRENT
callback is triggered
periodically. A value of 0 turns the callback off.
The CALLBACK_CURRENT
callback is only triggered if the current has changed since
the last triggering.
BrickletCurrent25.
get_current_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the period as set by set_current_callback_period
.
BrickletCurrent25.
set_analog_value_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the CALLBACK_ANALOG_VALUE
callback is triggered
periodically. A value of 0 turns the callback off.
The CALLBACK_ANALOG_VALUE
callback is only triggered if the analog value has
changed since the last triggering.
BrickletCurrent25.
get_analog_value_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the period as set by set_analog_value_callback_period
.
BrickletCurrent25.
set_current_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the thresholds for the CALLBACK_CURRENT_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the current is outside the min and max values |
'i' | Callback is triggered when the current is inside the min and max values |
'<' | Callback is triggered when the current is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the current is greater than the min value (max is ignored) |
The following meanings are defined for the elements of this function:
For option:
BrickletCurrent25.
get_current_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the threshold as set by set_current_callback_threshold
.
The following meanings are defined for the elements of this function:
For option:
BrickletCurrent25.
set_analog_value_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the thresholds for the CALLBACK_ANALOG_VALUE_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the analog value is outside the min and max values |
'i' | Callback is triggered when the analog value is inside the min and max values |
'<' | Callback is triggered when the analog value is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the analog value is greater than the min value (max is ignored) |
The following meanings are defined for the elements of this function:
For option:
BrickletCurrent25.
get_analog_value_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the threshold as set by set_analog_value_callback_threshold
.
The following meanings are defined for the elements of this function:
For option:
BrickletCurrent25.
set_debounce_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the threshold callbacks
are triggered, if the thresholds
keep being reached.
BrickletCurrent25.
get_debounce_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the debounce period as set by set_debounce_period
.
BrickletCurrent25.
CALLBACK_CURRENT
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered periodically with the period that is set by
set_current_callback_period
. The response value is the current of the
sensor.
The CALLBACK_CURRENT
callback is only triggered if the current has changed since the
last triggering.
BrickletCurrent25.
CALLBACK_ANALOG_VALUE
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered periodically with the period that is set by
set_analog_value_callback_period
. The response value is the analog value of the
sensor.
The CALLBACK_ANALOG_VALUE
callback is only triggered if the current has changed since the
last triggering.
BrickletCurrent25.
CALLBACK_CURRENT_REACHED
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered when the threshold as set by
set_current_callback_threshold
is reached.
The response value is the current of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by set_debounce_period
.
BrickletCurrent25.
CALLBACK_ANALOG_VALUE_REACHED
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered when the threshold as set by
set_analog_value_callback_threshold
is reached.
The response value is the analog value of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by set_debounce_period
.
BrickletCurrent25.
CALLBACK_OVER_CURRENT
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered when an over current is measured
(see is_over_current
).