This is the description of the TCP/IP protocol for the Voltage/Current Bricklet. General information and technical specifications for the Voltage/Current Bricklet are summarized in its hardware description.
A general description of the TCP/IP protocol structure can be found here.
BrickletVoltageCurrent.
get_current
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the current.
If you want to get the current periodically, it is recommended to use the
CALLBACK_CURRENT
callback and set the period with
set_current_callback_period
.
BrickletVoltageCurrent.
get_voltage
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the voltage.
If you want to get the voltage periodically, it is recommended to use the
CALLBACK_VOLTAGE
callback and set the period with
set_voltage_callback_period
.
BrickletVoltageCurrent.
get_power
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the power.
If you want to get the power periodically, it is recommended to use the
CALLBACK_POWER
callback and set the period with
set_power_callback_period
.
BrickletVoltageCurrent.
set_configuration
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the configuration of the Voltage/Current Bricklet. It is possible to configure number of averages as well as voltage and current conversion time.
The following meanings are defined for the elements of this function:
For averaging:
For voltage_conversion_time:
For current_conversion_time:
BrickletVoltageCurrent.
get_configuration
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the configuration as set by set_configuration
.
The following meanings are defined for the elements of this function:
For averaging:
For voltage_conversion_time:
For current_conversion_time:
BrickletVoltageCurrent.
set_calibration
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Since the shunt resistor that is used to measure the current is not perfectly precise, it needs to be calibrated by a multiplier and divisor if a very precise reading is needed.
For example, if you are expecting a measurement of 1000mA and you are measuring 1023mA, you can calibrate the Voltage/Current Bricklet by setting the multiplier to 1000 and the divisor to 1023.
BrickletVoltageCurrent.
get_calibration
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the calibration as set by set_calibration
.
BrickletVoltageCurrent.
get_identity
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here.
BrickletVoltageCurrent.
set_current_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the CALLBACK_CURRENT
callback is triggered
periodically. A value of 0 turns the callback off.
The CALLBACK_CURRENT
callback is only triggered if the current has changed since
the last triggering.
BrickletVoltageCurrent.
get_current_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the period as set by set_current_callback_period
.
BrickletVoltageCurrent.
set_voltage_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the CALLBACK_VOLTAGE
callback is triggered
periodically. A value of 0 turns the callback off.
The CALLBACK_VOLTAGE
callback is only triggered if the voltage has changed since
the last triggering.
BrickletVoltageCurrent.
get_voltage_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the period as set by set_voltage_callback_period
.
BrickletVoltageCurrent.
set_power_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the CALLBACK_POWER
callback is triggered
periodically. A value of 0 turns the callback off.
The CALLBACK_POWER
callback is only triggered if the power has changed since the
last triggering.
BrickletVoltageCurrent.
get_power_callback_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the period as set by get_power_callback_period
.
BrickletVoltageCurrent.
set_current_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the thresholds for the CALLBACK_CURRENT_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the current is outside the min and max values |
'i' | Callback is triggered when the current is inside the min and max values |
'<' | Callback is triggered when the current is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the current is greater than the min value (max is ignored) |
The following meanings are defined for the elements of this function:
For option:
BrickletVoltageCurrent.
get_current_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the threshold as set by set_current_callback_threshold
.
The following meanings are defined for the elements of this function:
For option:
BrickletVoltageCurrent.
set_voltage_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the thresholds for the CALLBACK_VOLTAGE_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the voltage is outside the min and max values |
'i' | Callback is triggered when the voltage is inside the min and max values |
'<' | Callback is triggered when the voltage is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the voltage is greater than the min value (max is ignored) |
The following meanings are defined for the elements of this function:
For option:
BrickletVoltageCurrent.
get_voltage_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the threshold as set by set_voltage_callback_threshold
.
The following meanings are defined for the elements of this function:
For option:
BrickletVoltageCurrent.
set_power_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the thresholds for the CALLBACK_POWER_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the power is outside the min and max values |
'i' | Callback is triggered when the power is inside the min and max values |
'<' | Callback is triggered when the power is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the power is greater than the min value (max is ignored) |
The following meanings are defined for the elements of this function:
For option:
BrickletVoltageCurrent.
get_power_callback_threshold
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the threshold as set by set_power_callback_threshold
.
The following meanings are defined for the elements of this function:
For option:
BrickletVoltageCurrent.
set_debounce_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Sets the period with which the threshold callbacks
are triggered, if the thresholds
keep being reached.
BrickletVoltageCurrent.
get_debounce_period
¶Function ID: |
|
---|---|
Request: |
|
Response: |
|
Returns the debounce period as set by set_debounce_period
.
BrickletVoltageCurrent.
CALLBACK_CURRENT
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered periodically with the period that is set by
set_current_callback_period
. The response value is the current of the
sensor.
The CALLBACK_CURRENT
callback is only triggered if the current has changed since
the last triggering.
BrickletVoltageCurrent.
CALLBACK_VOLTAGE
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered periodically with the period that is set by
set_voltage_callback_period
. The response value is the voltage of
the sensor.
The CALLBACK_VOLTAGE
callback is only triggered if the voltage has changed since
the last triggering.
BrickletVoltageCurrent.
CALLBACK_POWER
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered periodically with the period that is set by
set_power_callback_period
. The response value is the power of the
sensor.
The CALLBACK_POWER
callback is only triggered if the power has changed since the
last triggering.
BrickletVoltageCurrent.
CALLBACK_CURRENT_REACHED
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered when the threshold as set by
set_current_callback_threshold
is reached.
The response value is the current of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by set_debounce_period
.
BrickletVoltageCurrent.
CALLBACK_VOLTAGE_REACHED
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered when the threshold as set by
set_voltage_callback_threshold
is reached.
The response value is the voltage of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by set_debounce_period
.
BrickletVoltageCurrent.
CALLBACK_POWER_REACHED
¶Function ID: |
|
---|---|
Response: |
|
This callback is triggered when the threshold as set by
set_power_callback_threshold
is reached.
The response value is the power of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by set_debounce_period
.