This is the description of the Visual Basic .NET API bindings for the Analog In Bricklet 2.0. General information and technical specifications for the Analog In Bricklet 2.0 are summarized in its hardware description.
An installation guide for the Visual Basic .NET API bindings is part of their general description.
The example code below is Public Domain (CC0 1.0).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 | Imports System
Imports Tinkerforge
Module ExampleSimple
Const HOST As String = "localhost"
Const PORT As Integer = 4223
Const UID As String = "XYZ" ' Change XYZ to the UID of your Analog In Bricklet 2.0
Sub Main()
Dim ipcon As New IPConnection() ' Create IP connection
Dim ai As New BrickletAnalogInV2(UID, ipcon) ' Create device object
ipcon.Connect(HOST, PORT) ' Connect to brickd
' Don't use device before ipcon is connected
' Get current voltage
Dim voltage As Integer = ai.GetVoltage()
Console.WriteLine("Voltage: " + (voltage/1000.0).ToString() + " V")
Console.WriteLine("Press key to exit")
Console.ReadLine()
ipcon.Disconnect()
End Sub
End Module
|
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 | Imports System
Imports Tinkerforge
Module ExampleCallback
Const HOST As String = "localhost"
Const PORT As Integer = 4223
Const UID As String = "XYZ" ' Change XYZ to the UID of your Analog In Bricklet 2.0
' Callback subroutine for voltage callback
Sub VoltageCB(ByVal sender As BrickletAnalogInV2, ByVal voltage As Integer)
Console.WriteLine("Voltage: " + (voltage/1000.0).ToString() + " V")
End Sub
Sub Main()
Dim ipcon As New IPConnection() ' Create IP connection
Dim ai As New BrickletAnalogInV2(UID, ipcon) ' Create device object
ipcon.Connect(HOST, PORT) ' Connect to brickd
' Don't use device before ipcon is connected
' Register voltage callback to subroutine VoltageCB
AddHandler ai.VoltageCallback, AddressOf VoltageCB
' Set period for voltage callback to 1s (1000ms)
' Note: The voltage callback is only called every second
' if the voltage has changed since the last call!
ai.SetVoltageCallbackPeriod(1000)
Console.WriteLine("Press key to exit")
Console.ReadLine()
ipcon.Disconnect()
End Sub
End Module
|
Download (ExampleThreshold.vb)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 | Imports System
Imports Tinkerforge
Module ExampleThreshold
Const HOST As String = "localhost"
Const PORT As Integer = 4223
Const UID As String = "XYZ" ' Change XYZ to the UID of your Analog In Bricklet 2.0
' Callback subroutine for voltage reached callback
Sub VoltageReachedCB(ByVal sender As BrickletAnalogInV2, ByVal voltage As Integer)
Console.WriteLine("Voltage: " + (voltage/1000.0).ToString() + " V")
End Sub
Sub Main()
Dim ipcon As New IPConnection() ' Create IP connection
Dim ai As New BrickletAnalogInV2(UID, ipcon) ' Create device object
ipcon.Connect(HOST, PORT) ' Connect to brickd
' Don't use device before ipcon is connected
' Get threshold callbacks with a debounce time of 10 seconds (10000ms)
ai.SetDebouncePeriod(10000)
' Register voltage reached callback to subroutine VoltageReachedCB
AddHandler ai.VoltageReachedCallback, AddressOf VoltageReachedCB
' Configure threshold for voltage "smaller than 5 V"
ai.SetVoltageCallbackThreshold("<"C, 5*1000, 0)
Console.WriteLine("Press key to exit")
Console.ReadLine()
ipcon.Disconnect()
End Sub
End Module
|
Since Visual Basic .NET does not support multiple return values directly, we
use the ByRef
keyword to return multiple values from a function.
All functions and procedures listed below are thread-safe.
BrickletAnalogInV2
(ByVal uid As String, ByVal ipcon As IPConnection)¶Creates an object with the unique device ID uid
:
Dim analogInV2 As New BrickletAnalogInV2("YOUR_DEVICE_UID", ipcon)
This object can then be used after the IP Connection is connected.
BrickletAnalogInV2.
GetVoltage
() As Integer¶Returns: |
|
---|
Returns the measured voltage. The resolution is approximately 10mV.
If you want to get the voltage periodically, it is recommended to use the
VoltageCallback
callback and set the period with
SetVoltageCallbackPeriod()
.
BrickletAnalogInV2.
GetAnalogValue
() As Integer¶Returns: |
|
---|
Returns the value as read by a 12-bit analog-to-digital converter.
If you want the analog value periodically, it is recommended to use the
AnalogValueCallback
callback and set the period with
SetAnalogValueCallbackPeriod()
.
BrickletAnalogInV2.
SetMovingAverage
(ByVal average As Byte)¶Parameters: |
|
---|
Sets the length of a moving averaging for the voltage.
Setting the length to 1 will turn the averaging off. With less averaging, there is more noise on the data.
BrickletAnalogInV2.
GetMovingAverage
() As Byte¶Returns: |
|
---|
Returns the length of the moving average as set by SetMovingAverage()
.
BrickletAnalogInV2.
GetIdentity
(ByRef uid As String, ByRef connectedUid As String, ByRef position As Char, ByRef hardwareVersion() As Byte, ByRef firmwareVersion() As Byte, ByRef deviceIdentifier As Integer)¶Output Parameters: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.
BrickletAnalogInV2.
SetVoltageCallbackPeriod
(ByVal period As Long)¶Parameters: |
|
---|
Sets the period with which the VoltageCallback
callback is triggered
periodically. A value of 0 turns the callback off.
The VoltageCallback
callback is only triggered if the voltage has changed since
the last triggering.
BrickletAnalogInV2.
GetVoltageCallbackPeriod
() As Long¶Returns: |
|
---|
Returns the period as set by SetVoltageCallbackPeriod()
.
BrickletAnalogInV2.
SetAnalogValueCallbackPeriod
(ByVal period As Long)¶Parameters: |
|
---|
Sets the period with which the AnalogValueCallback
callback is triggered
periodically. A value of 0 turns the callback off.
The AnalogValueCallback
callback is only triggered if the analog value has
changed since the last triggering.
BrickletAnalogInV2.
GetAnalogValueCallbackPeriod
() As Long¶Returns: |
|
---|
Returns the period as set by SetAnalogValueCallbackPeriod()
.
BrickletAnalogInV2.
SetVoltageCallbackThreshold
(ByVal option As Char, ByVal min As Integer, ByVal max As Integer)¶Parameters: |
|
---|
Sets the thresholds for the VoltageReachedCallback
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the voltage is outside the min and max values |
'i' | Callback is triggered when the voltage is inside the min and max values |
'<' | Callback is triggered when the voltage is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the voltage is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletAnalogInV2.
GetVoltageCallbackThreshold
(ByRef option As Char, ByRef min As Integer, ByRef max As Integer)¶Output Parameters: |
|
---|
Returns the threshold as set by SetVoltageCallbackThreshold()
.
The following constants are available for this function:
For option:
BrickletAnalogInV2.
SetAnalogValueCallbackThreshold
(ByVal option As Char, ByVal min As Integer, ByVal max As Integer)¶Parameters: |
|
---|
Sets the thresholds for the AnalogValueReachedCallback
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the analog value is outside the min and max values |
'i' | Callback is triggered when the analog value is inside the min and max values |
'<' | Callback is triggered when the analog value is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the analog value is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletAnalogInV2.
GetAnalogValueCallbackThreshold
(ByRef option As Char, ByRef min As Integer, ByRef max As Integer)¶Output Parameters: |
|
---|
Returns the threshold as set by SetAnalogValueCallbackThreshold()
.
The following constants are available for this function:
For option:
BrickletAnalogInV2.
SetDebouncePeriod
(ByVal debounce As Long)¶Parameters: |
|
---|
Sets the period with which the threshold callbacks
are triggered, if the thresholds
keep being reached.
BrickletAnalogInV2.
GetDebouncePeriod
() As Long¶Returns: |
|
---|
Returns the debounce period as set by SetDebouncePeriod()
.
Callbacks can be registered to receive time critical or recurring data from the device. The registration is done by assigning a procedure to an callback property of the device object:
Sub MyCallback(ByVal sender As BrickletAnalogInV2, ByVal value As Short) Console.WriteLine("Value: {0}", value) End Sub AddHandler analogInV2.ExampleCallback, AddressOf MyCallback
The available callback property and their type of parameters are described below.
Note
Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.
BrickletAnalogInV2.
VoltageCallback
(ByVal sender As BrickletAnalogInV2, ByVal voltage As Integer)¶Callback Parameters: |
|
---|
This callback is triggered periodically with the period that is set by
SetVoltageCallbackPeriod()
. The parameter is the voltage of the
sensor.
Der VoltageCallback
callback is only triggered if the voltage has changed since
the last triggering.
BrickletAnalogInV2.
AnalogValueCallback
(ByVal sender As BrickletAnalogInV2, ByVal value As Integer)¶Callback Parameters: |
|
---|
This callback is triggered periodically with the period that is set by
SetAnalogValueCallbackPeriod()
. The parameter is the analog
value of the sensor.
The AnalogValueCallback
callback is only triggered if the voltage has changed
since the last triggering.
BrickletAnalogInV2.
VoltageReachedCallback
(ByVal sender As BrickletAnalogInV2, ByVal voltage As Integer)¶Callback Parameters: |
|
---|
This callback is triggered when the threshold as set by
SetVoltageCallbackThreshold()
is reached.
The parameter is the voltage of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by SetDebouncePeriod()
.
BrickletAnalogInV2.
AnalogValueReachedCallback
(ByVal sender As BrickletAnalogInV2, ByVal value As Integer)¶Callback Parameters: |
|
---|
This callback is triggered when the threshold as set by
SetAnalogValueCallbackThreshold()
is reached.
The parameter is the analog value of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by SetDebouncePeriod()
.
Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.
BrickletAnalogInV2.
GetAPIVersion
() As Byte()¶Output Parameters: |
|
---|
Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
BrickletAnalogInV2.
GetResponseExpected
(ByVal functionId As Byte) As Boolean¶Parameters: |
|
---|---|
Returns: |
|
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled,
because those functions will always send a response. For callback configuration
functions it is enabled by default too, but can be disabled by
SetResponseExpected()
. For setter functions it is disabled by default
and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletAnalogInV2.
SetResponseExpected
(ByVal functionId As Byte, ByVal responseExpected As Boolean)¶Parameters: |
|
---|
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletAnalogInV2.
SetResponseExpectedAll
(ByVal responseExpected As Boolean)¶Parameters: |
|
---|
Changes the response expected flag for all setter and callback configuration functions of this device at once.
BrickletAnalogInV2.
DEVICE_IDENTIFIER
¶This constant is used to identify a Analog In Bricklet 2.0.
The GetIdentity()
function and the
IPConnection.EnumerateCallback
callback of the IP Connection have a deviceIdentifier
parameter to specify
the Brick's or Bricklet's type.
BrickletAnalogInV2.
DEVICE_DISPLAY_NAME
¶This constant represents the human readable name of a Analog In Bricklet 2.0.