Modbus - Voltage Bricklet

This is the description of the Modbus protocol for the Voltage Bricklet. General information and technical specifications for the Voltage Bricklet are summarized in its hardware description.

API

A general description of the Modbus protocol structure can be found here.

Basic Functions

BrickletVoltage.get_voltage
Function ID:
  • 1
Request:
  • empty payload
Response:
  • voltage – Type: uint16, Unit: 1 mV, Range: [0 to 50000]

Returns the voltage of the sensor.

If you want to get the voltage periodically, it is recommended to use the CALLBACK_VOLTAGE callback and set the period with set_voltage_callback_period.

Advanced Functions

BrickletVoltage.get_analog_value
Function ID:
  • 2
Request:
  • empty payload
Response:
  • value – Type: uint16, Range: [0 to 212 - 1]

Returns the value as read by a 12-bit analog-to-digital converter.

Note

The value returned by get_voltage is averaged over several samples to yield less noise, while get_analog_value gives back raw unfiltered analog values. The only reason to use get_analog_value is, if you need the full resolution of the analog-to-digital converter.

If you want the analog value periodically, it is recommended to use the CALLBACK_ANALOG_VALUE callback and set the period with set_analog_value_callback_period.

BrickletVoltage.get_identity
Function ID:
  • 255
Request:
  • empty payload
Response:
  • uid – Type: char[8]
  • connected_uid – Type: char[8]
  • position – Type: char, Range: ['a' to 'h', 'z']
  • hardware_version – Type: uint8[3]
    • 0: major – Type: uint8, Range: [0 to 255]
    • 1: minor – Type: uint8, Range: [0 to 255]
    • 2: revision – Type: uint8, Range: [0 to 255]
  • firmware_version – Type: uint8[3]
    • 0: major – Type: uint8, Range: [0 to 255]
    • 1: minor – Type: uint8, Range: [0 to 255]
    • 2: revision – Type: uint8, Range: [0 to 255]
  • device_identifier – Type: uint16, Range: [0 to 216 - 1]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here

Callback Configuration Functions

BrickletVoltage.set_voltage_callback_period
Function ID:
  • 3
Request:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
Response:
  • no response

Sets the period with which the CALLBACK_VOLTAGE callback is triggered periodically. A value of 0 turns the callback off.

The CALLBACK_VOLTAGE callback is only triggered if the voltage has changed since the last triggering.

BrickletVoltage.get_voltage_callback_period
Function ID:
  • 4
Request:
  • empty payload
Response:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0

Returns the period as set by set_voltage_callback_period.

BrickletVoltage.set_analog_value_callback_period
Function ID:
  • 5
Request:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
Response:
  • no response

Sets the period with which the CALLBACK_ANALOG_VALUE callback is triggered periodically. A value of 0 turns the callback off.

The CALLBACK_ANALOG_VALUE callback is only triggered if the analog value has changed since the last triggering.

BrickletVoltage.get_analog_value_callback_period
Function ID:
  • 6
Request:
  • empty payload
Response:
  • period – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0

Returns the period as set by set_analog_value_callback_period.

BrickletVoltage.set_voltage_callback_threshold
Function ID:
  • 7
Request:
  • option – Type: char, Range: See meanings, Default: 'x'
  • min – Type: uint16, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0
  • max – Type: uint16, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0
Response:
  • no response

Sets the thresholds for the CALLBACK_VOLTAGE_REACHED callback.

The following options are possible:

Option Description
'x' Callback is turned off
'o' Callback is triggered when the voltage is outside the min and max values
'i' Callback is triggered when the voltage is inside the min and max values
'<' Callback is triggered when the voltage is smaller than the min value (max is ignored)
'>' Callback is triggered when the voltage is greater than the min value (max is ignored)

The following meanings are defined for the elements of this function:

For option:

  • 'x' = Off
  • 'o' = Outside
  • 'i' = Inside
  • '<' = Smaller
  • '>' = Greater
BrickletVoltage.get_voltage_callback_threshold
Function ID:
  • 8
Request:
  • empty payload
Response:
  • option – Type: char, Range: See meanings, Default: 'x'
  • min – Type: uint16, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0
  • max – Type: uint16, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0

Returns the threshold as set by set_voltage_callback_threshold.

The following meanings are defined for the elements of this function:

For option:

  • 'x' = Off
  • 'o' = Outside
  • 'i' = Inside
  • '<' = Smaller
  • '>' = Greater
BrickletVoltage.set_analog_value_callback_threshold
Function ID:
  • 9
Request:
  • option – Type: char, Range: See meanings, Default: 'x'
  • min – Type: uint16, Range: [0 to 216 - 1], Default: 0
  • max – Type: uint16, Range: [0 to 216 - 1], Default: 0
Response:
  • no response

Sets the thresholds for the CALLBACK_ANALOG_VALUE_REACHED callback.

The following options are possible:

Option Description
'x' Callback is turned off
'o' Callback is triggered when the analog value is outside the min and max values
'i' Callback is triggered when the analog value is inside the min and max values
'<' Callback is triggered when the analog value is smaller than the min value (max is ignored)
'>' Callback is triggered when the analog value is greater than the min value (max is ignored)

The following meanings are defined for the elements of this function:

For option:

  • 'x' = Off
  • 'o' = Outside
  • 'i' = Inside
  • '<' = Smaller
  • '>' = Greater
BrickletVoltage.get_analog_value_callback_threshold
Function ID:
  • 10
Request:
  • empty payload
Response:
  • option – Type: char, Range: See meanings, Default: 'x'
  • min – Type: uint16, Range: [0 to 216 - 1], Default: 0
  • max – Type: uint16, Range: [0 to 216 - 1], Default: 0

Returns the threshold as set by set_analog_value_callback_threshold.

The following meanings are defined for the elements of this function:

For option:

  • 'x' = Off
  • 'o' = Outside
  • 'i' = Inside
  • '<' = Smaller
  • '>' = Greater
BrickletVoltage.set_debounce_period
Function ID:
  • 11
Request:
  • debounce – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 100
Response:
  • no response

Sets the period with which the threshold callbacks

are triggered, if the thresholds

keep being reached.

BrickletVoltage.get_debounce_period
Function ID:
  • 12
Request:
  • empty payload
Response:
  • debounce – Type: uint32, Unit: 1 ms, Range: [0 to 232 - 1], Default: 100

Returns the debounce period as set by set_debounce_period.

Callbacks

BrickletVoltage.CALLBACK_VOLTAGE
Function ID:
  • 13
Response:
  • voltage – Type: uint16, Unit: 1 mV, Range: [0 to 50000]

This callback is triggered periodically with the period that is set by set_voltage_callback_period. The response value is the voltage of the sensor.

The CALLBACK_VOLTAGE callback is only triggered if the voltage has changed since the last triggering.

BrickletVoltage.CALLBACK_ANALOG_VALUE
Function ID:
  • 14
Response:
  • value – Type: uint16, Range: [0 to 212 - 1]

This callback is triggered periodically with the period that is set by set_analog_value_callback_period. The response value is the analog value of the sensor.

The CALLBACK_ANALOG_VALUE callback is only triggered if the voltage has changed since the last triggering.

BrickletVoltage.CALLBACK_VOLTAGE_REACHED
Function ID:
  • 15
Response:
  • voltage – Type: uint16, Unit: 1 mV, Range: [0 to 50000]

This callback is triggered when the threshold as set by set_voltage_callback_threshold is reached. The response value is the voltage of the sensor.

If the threshold keeps being reached, the callback is triggered periodically with the period as set by set_debounce_period.

BrickletVoltage.CALLBACK_ANALOG_VALUE_REACHED
Function ID:
  • 16
Response:
  • value – Type: uint16, Range: [0 to 212 - 1]

This callback is triggered when the threshold as set by set_analog_value_callback_threshold is reached. The response value is the analog value of the sensor.

If the threshold keeps being reached, the callback is triggered periodically with the period as set by set_debounce_period.