This is the description of the C# API bindings for the Moisture Bricklet. General information and technical specifications for the Moisture Bricklet are summarized in its hardware description.
An installation guide for the C# API bindings is part of their general description.
The example code below is Public Domain (CC0 1.0).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 | using System;
using Tinkerforge;
class Example
{
private static string HOST = "localhost";
private static int PORT = 4223;
private static string UID = "XYZ"; // Change XYZ to the UID of your Moisture Bricklet
static void Main()
{
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletMoisture m = new BrickletMoisture(UID, ipcon); // Create device object
ipcon.Connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Get current moisture value
int moisture = m.GetMoistureValue();
Console.WriteLine("Moisture Value: " + moisture);
Console.WriteLine("Press enter to exit");
Console.ReadLine();
ipcon.Disconnect();
}
}
|
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 | using System;
using Tinkerforge;
class Example
{
private static string HOST = "localhost";
private static int PORT = 4223;
private static string UID = "XYZ"; // Change XYZ to the UID of your Moisture Bricklet
// Callback function for moisture value callback
static void MoistureCB(BrickletMoisture sender, int moisture)
{
Console.WriteLine("Moisture Value: " + moisture);
}
static void Main()
{
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletMoisture m = new BrickletMoisture(UID, ipcon); // Create device object
ipcon.Connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Register moisture value callback to function MoistureCB
m.MoistureCallback += MoistureCB;
// Set period for moisture value callback to 1s (1000ms)
// Note: The moisture value callback is only called every second
// if the moisture value has changed since the last call!
m.SetMoistureCallbackPeriod(1000);
Console.WriteLine("Press enter to exit");
Console.ReadLine();
ipcon.Disconnect();
}
}
|
Download (ExampleThreshold.cs)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 | using System;
using Tinkerforge;
class Example
{
private static string HOST = "localhost";
private static int PORT = 4223;
private static string UID = "XYZ"; // Change XYZ to the UID of your Moisture Bricklet
// Callback function for moisture value reached callback
static void MoistureReachedCB(BrickletMoisture sender, int moisture)
{
Console.WriteLine("Moisture Value: " + moisture);
}
static void Main()
{
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletMoisture m = new BrickletMoisture(UID, ipcon); // Create device object
ipcon.Connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Get threshold callbacks with a debounce time of 1 second (1000ms)
m.SetDebouncePeriod(1000);
// Register moisture value reached callback to function MoistureReachedCB
m.MoistureReachedCallback += MoistureReachedCB;
// Configure threshold for moisture value "greater than 200"
m.SetMoistureCallbackThreshold('>', 200, 0);
Console.WriteLine("Press enter to exit");
Console.ReadLine();
ipcon.Disconnect();
}
}
|
Generally, every method of the C# bindings that returns a value can
throw a Tinkerforge.TimeoutException
. This exception gets thrown if the
device did not respond. If a cable based connection is used, it is
unlikely that this exception gets thrown (assuming nobody plugs the
device out). However, if a wireless connection is used, timeouts will occur
if the distance to the device gets too big.
Since C# does not support multiple return values directly, we use the out
keyword to return multiple values from a method.
The namespace for all Brick/Bricklet bindings and the IPConnection is
Tinkerforge.*
.
All methods listed below are thread-safe.
BrickletMoisture
(string uid, IPConnection ipcon)¶Parameters: |
|
---|---|
Returns: |
|
Creates an object with the unique device ID uid
:
BrickletMoisture moisture = new BrickletMoisture("YOUR_DEVICE_UID", ipcon);
This object can then be used after the IP Connection is connected.
BrickletMoisture.
GetMoistureValue
()¶Returns: |
|
---|
Returns the current moisture value. A small value corresponds to little moisture, a big value corresponds to much moisture.
If you want to get the moisture value periodically, it is recommended
to use the MoistureCallback
callback and set the period with
SetMoistureCallbackPeriod()
.
BrickletMoisture.
SetMovingAverage
(byte average)¶Parameters: |
|
---|
Sets the length of a moving averaging for the moisture value.
Setting the length to 0 will turn the averaging completely off. With less averaging, there is more noise on the data.
BrickletMoisture.
GetMovingAverage
()¶Returns: |
|
---|
Returns the length moving average as set by SetMovingAverage()
.
BrickletMoisture.
GetIdentity
(out string uid, out string connectedUid, out char position, out byte[] hardwareVersion, out byte[] firmwareVersion, out int deviceIdentifier)¶Output Parameters: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.
BrickletMoisture.
SetMoistureCallbackPeriod
(long period)¶Parameters: |
|
---|
Sets the period with which the MoistureCallback
callback is triggered
periodically. A value of 0 turns the callback off.
The MoistureCallback
callback is only triggered if the moisture value has changed
since the last triggering.
BrickletMoisture.
GetMoistureCallbackPeriod
()¶Returns: |
|
---|
Returns the period as set by SetMoistureCallbackPeriod()
.
BrickletMoisture.
SetMoistureCallbackThreshold
(char option, int min, int max)¶Parameters: |
|
---|
Sets the thresholds for the MoistureReachedCallback
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the moisture value is outside the min and max values |
'i' | Callback is triggered when the moisture value is inside the min and max values |
'<' | Callback is triggered when the moisture value is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the moisture value is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletMoisture.
GetMoistureCallbackThreshold
(out char option, out int min, out int max)¶Output Parameters: |
|
---|
Returns the threshold as set by SetMoistureCallbackThreshold()
.
The following constants are available for this function:
For option:
BrickletMoisture.
SetDebouncePeriod
(long debounce)¶Parameters: |
|
---|
Sets the period with which the threshold callback
is triggered, if the threshold
keeps being reached.
BrickletMoisture.
GetDebouncePeriod
()¶Returns: |
|
---|
Returns the debounce period as set by SetDebouncePeriod()
.
Callbacks can be registered to receive time critical or recurring data from the device. The registration is done by appending your callback handler to the corresponding event:
void MyCallback(BrickletMoisture sender, int value)
{
System.Console.WriteLine("Value: " + value);
}
moisture.ExampleCallback += MyCallback;
The available events are described below.
Note
Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.
BrickletMoisture.
MoistureCallback
(BrickletMoisture sender, int moisture)¶Callback Parameters: |
|
---|
This callback is triggered periodically with the period that is set by
SetMoistureCallbackPeriod()
. The parameter is the
moisture value of the sensor.
The MoistureCallback
callback is only triggered if the moisture value has changed
since the last triggering.
BrickletMoisture.
MoistureReachedCallback
(BrickletMoisture sender, int moisture)¶Callback Parameters: |
|
---|
This callback is triggered when the threshold as set by
SetMoistureCallbackThreshold()
is reached.
The parameter is the moisture value of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by SetDebouncePeriod()
.
Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.
BrickletMoisture.
GetAPIVersion
()¶Output Parameters: |
|
---|
Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
BrickletMoisture.
GetResponseExpected
(byte functionId)¶Parameters: |
|
---|---|
Returns: |
|
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled,
because those functions will always send a response. For callback configuration
functions it is enabled by default too, but can be disabled by
SetResponseExpected()
. For setter functions it is disabled by default
and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletMoisture.
SetResponseExpected
(byte functionId, bool responseExpected)¶Parameters: |
|
---|
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletMoisture.
SetResponseExpectedAll
(bool responseExpected)¶Parameters: |
|
---|
Changes the response expected flag for all setter and callback configuration functions of this device at once.
BrickletMoisture.
DEVICE_IDENTIFIER
¶This constant is used to identify a Moisture Bricklet.
The GetIdentity()
function and the
IPConnection.EnumerateCallback
callback of the IP Connection have a deviceIdentifier
parameter to specify
the Brick's or Bricklet's type.
BrickletMoisture.
DEVICE_DISPLAY_NAME
¶This constant represents the human readable name of a Moisture Bricklet.