Java - Analog In Bricklet 3.0

This is the description of the Java API bindings for the Analog In Bricklet 3.0. General information and technical specifications for the Analog In Bricklet 3.0 are summarized in its hardware description.

An installation guide for the Java API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Simple

Download (ExampleSimple.java)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletAnalogInV3;

public class ExampleSimple {
    private static final String HOST = "localhost";
    private static final int PORT = 4223;

    // Change XYZ to the UID of your Analog In Bricklet 3.0
    private static final String UID = "XYZ";

    // Note: To make the example code cleaner we do not handle exceptions. Exceptions
    //       you might normally want to catch are described in the documentation
    public static void main(String args[]) throws Exception {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletAnalogInV3 ai = new BrickletAnalogInV3(UID, ipcon); // Create device object

        ipcon.connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Get current voltage
        int voltage = ai.getVoltage(); // Can throw com.tinkerforge.TimeoutException
        System.out.println("Voltage: " + voltage/1000.0 + " V");

        System.out.println("Press key to exit"); System.in.read();
        ipcon.disconnect();
    }
}

Callback

Download (ExampleCallback.java)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletAnalogInV3;

public class ExampleCallback {
    private static final String HOST = "localhost";
    private static final int PORT = 4223;

    // Change XYZ to the UID of your Analog In Bricklet 3.0
    private static final String UID = "XYZ";

    // Note: To make the example code cleaner we do not handle exceptions. Exceptions
    //       you might normally want to catch are described in the documentation
    public static void main(String args[]) throws Exception {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletAnalogInV3 ai = new BrickletAnalogInV3(UID, ipcon); // Create device object

        ipcon.connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Add voltage listener
        ai.addVoltageListener(new BrickletAnalogInV3.VoltageListener() {
            public void voltage(int voltage) {
                System.out.println("Voltage: " + voltage/1000.0 + " V");
            }
        });

        // Set period for voltage callback to 1s (1000ms) without a threshold
        ai.setVoltageCallbackConfiguration(1000, false, 'x', 0, 0);

        System.out.println("Press key to exit"); System.in.read();
        ipcon.disconnect();
    }
}

Threshold

Download (ExampleThreshold.java)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletAnalogInV3;

public class ExampleThreshold {
    private static final String HOST = "localhost";
    private static final int PORT = 4223;

    // Change XYZ to the UID of your Analog In Bricklet 3.0
    private static final String UID = "XYZ";

    // Note: To make the example code cleaner we do not handle exceptions. Exceptions
    //       you might normally want to catch are described in the documentation
    public static void main(String args[]) throws Exception {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletAnalogInV3 ai = new BrickletAnalogInV3(UID, ipcon); // Create device object

        ipcon.connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Add voltage listener
        ai.addVoltageListener(new BrickletAnalogInV3.VoltageListener() {
            public void voltage(int voltage) {
                System.out.println("Voltage: " + voltage/1000.0 + " V");
            }
        });

        // Configure threshold for voltage "smaller than 5 V"
        // with a debounce period of 1s (1000ms)
        ai.setVoltageCallbackConfiguration(1000, false, '<', 5*1000, 0);

        System.out.println("Press key to exit"); System.in.read();
        ipcon.disconnect();
    }
}

API

Generally, every method of the Java bindings that returns a value can throw a TimeoutException. This exception gets thrown if the device did not respond. If a cable based connection is used, it is unlikely that this exception gets thrown (assuming nobody unplugs the device). However, if a wireless connection is used, timeouts will occur if the distance to the device gets too big.

Beside the TimeoutException there is also a NotConnectedException that is thrown if a method needs to communicate with the device while the IP Connection is not connected.

Since Java does not support multiple return values and return by reference is not possible for primitive types, we use small classes that only consist of member variables. The member variables of the returned objects are described in the corresponding method descriptions.

The package for all Brick/Bricklet bindings and the IP Connection is com.tinkerforge.*

All methods listed below are thread-safe.

Basic Functions

class BrickletAnalogInV3(String uid, IPConnection ipcon)
Parameters:
  • uid – Type: String
  • ipcon – Type: IPConnection
Returns:
  • analogInV3 – Type: BrickletAnalogInV3

Creates an object with the unique device ID uid:

BrickletAnalogInV3 analogInV3 = new BrickletAnalogInV3("YOUR_DEVICE_UID", ipcon);

This object can then be used after the IP Connection is connected.

int BrickletAnalogInV3.getVoltage()
Returns:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 42000]

Returns the measured voltage. The resolution is approximately 10mV to 1mV depending on the oversampling configuration (setOversampling()).

If you want to get the value periodically, it is recommended to use the VoltageListener listener. You can set the listener configuration with setVoltageCallbackConfiguration().

Advanced Functions

void BrickletAnalogInV3.setOversampling(int oversampling)
Parameters:
  • oversampling – Type: int, Range: See constants, Default: 7

Sets the oversampling between 32x and 16384x. The Bricklet takes one 12bit sample every 17.5µs. Thus an oversampling of 32x is equivalent to an integration time of 0.56ms and a oversampling of 16384x is equivalent to an integration time of 286ms.

The oversampling uses the moving average principle. A new value is always calculated once per millisecond.

With increased oversampling the noise decreases. With decreased oversampling the reaction time increases (changes in voltage will be measured faster).

The following constants are available for this function:

For oversampling:

  • BrickletAnalogInV3.OVERSAMPLING_32 = 0
  • BrickletAnalogInV3.OVERSAMPLING_64 = 1
  • BrickletAnalogInV3.OVERSAMPLING_128 = 2
  • BrickletAnalogInV3.OVERSAMPLING_256 = 3
  • BrickletAnalogInV3.OVERSAMPLING_512 = 4
  • BrickletAnalogInV3.OVERSAMPLING_1024 = 5
  • BrickletAnalogInV3.OVERSAMPLING_2048 = 6
  • BrickletAnalogInV3.OVERSAMPLING_4096 = 7
  • BrickletAnalogInV3.OVERSAMPLING_8192 = 8
  • BrickletAnalogInV3.OVERSAMPLING_16384 = 9
int BrickletAnalogInV3.getOversampling()
Returns:
  • oversampling – Type: int, Range: See constants, Default: 7

Returns the oversampling value as set by setOversampling().

The following constants are available for this function:

For oversampling:

  • BrickletAnalogInV3.OVERSAMPLING_32 = 0
  • BrickletAnalogInV3.OVERSAMPLING_64 = 1
  • BrickletAnalogInV3.OVERSAMPLING_128 = 2
  • BrickletAnalogInV3.OVERSAMPLING_256 = 3
  • BrickletAnalogInV3.OVERSAMPLING_512 = 4
  • BrickletAnalogInV3.OVERSAMPLING_1024 = 5
  • BrickletAnalogInV3.OVERSAMPLING_2048 = 6
  • BrickletAnalogInV3.OVERSAMPLING_4096 = 7
  • BrickletAnalogInV3.OVERSAMPLING_8192 = 8
  • BrickletAnalogInV3.OVERSAMPLING_16384 = 9
void BrickletAnalogInV3.setCalibration(int offset, int multiplier, int divisor)
Parameters:
  • offset – Type: int, Unit: 1 mV, Range: [-215 to 215 - 1]
  • multiplier – Type: int, Range: [0 to 216 - 1]
  • divisor – Type: int, Range: [0 to 216 - 1]

Sets a calibration for the measured voltage value. The formula for the calibration is as follows:

Calibrated Value = (Value + Offset) * Multiplier / Divisor

We recommend that you use the Brick Viewer to calibrate the Bricklet. The calibration will be saved internally and only has to be done once.

BrickletAnalogInV3.Calibration BrickletAnalogInV3.getCalibration()
Return Object:
  • offset – Type: int, Unit: 1 mV, Range: [-215 to 215 - 1]
  • multiplier – Type: int, Range: [0 to 216 - 1]
  • divisor – Type: int, Range: [0 to 216 - 1]

Returns the calibration as set by setCalibration().

BrickletAnalogInV3.SPITFPErrorCount BrickletAnalogInV3.getSPITFPErrorCount()
Return Object:
  • errorCountAckChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountMessageChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountFrame – Type: long, Range: [0 to 232 - 1]
  • errorCountOverflow – Type: long, Range: [0 to 232 - 1]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

void BrickletAnalogInV3.setStatusLEDConfig(int config)
Parameters:
  • config – Type: int, Range: See constants, Default: 3

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following constants are available for this function:

For config:

  • BrickletAnalogInV3.STATUS_LED_CONFIG_OFF = 0
  • BrickletAnalogInV3.STATUS_LED_CONFIG_ON = 1
  • BrickletAnalogInV3.STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • BrickletAnalogInV3.STATUS_LED_CONFIG_SHOW_STATUS = 3
int BrickletAnalogInV3.getStatusLEDConfig()
Returns:
  • config – Type: int, Range: See constants, Default: 3

Returns the configuration as set by setStatusLEDConfig()

The following constants are available for this function:

For config:

  • BrickletAnalogInV3.STATUS_LED_CONFIG_OFF = 0
  • BrickletAnalogInV3.STATUS_LED_CONFIG_ON = 1
  • BrickletAnalogInV3.STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • BrickletAnalogInV3.STATUS_LED_CONFIG_SHOW_STATUS = 3
int BrickletAnalogInV3.getChipTemperature()
Returns:
  • temperature – Type: int, Unit: 1 °C, Range: [-215 to 215 - 1]

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

void BrickletAnalogInV3.reset()

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

BrickletAnalogInV3.Identity BrickletAnalogInV3.getIdentity()
Return Object:
  • uid – Type: String, Length: up to 8
  • connectedUid – Type: String, Length: up to 8
  • position – Type: char, Range: ['a' to 'h', 'z']
  • hardwareVersion – Type: short[], Length: 3
    • 0: major – Type: short, Range: [0 to 255]
    • 1: minor – Type: short, Range: [0 to 255]
    • 2: revision – Type: short, Range: [0 to 255]
  • firmwareVersion – Type: short[], Length: 3
    • 0: major – Type: short, Range: [0 to 255]
    • 1: minor – Type: short, Range: [0 to 255]
    • 2: revision – Type: short, Range: [0 to 255]
  • deviceIdentifier – Type: int, Range: [0 to 216 - 1]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Listener Configuration Functions

void BrickletAnalogInV3.setVoltageCallbackConfiguration(long period, boolean valueHasToChange, char option, int min, int max)
Parameters:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0
  • max – Type: int, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0

The period is the period with which the VoltageListener listener is triggered periodically. A value of 0 turns the listener off.

If the value has to change-parameter is set to true, the listener is only triggered after the value has changed. If the value didn't change within the period, the listener is triggered immediately on change.

If it is set to false, the listener is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the listener with thresholds.

The option-parameter together with min/max sets a threshold for the VoltageListener listener.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the listener is triggered with the fixed period.

The following constants are available for this function:

For option:

  • BrickletAnalogInV3.THRESHOLD_OPTION_OFF = 'x'
  • BrickletAnalogInV3.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletAnalogInV3.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletAnalogInV3.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletAnalogInV3.THRESHOLD_OPTION_GREATER = '>'
BrickletAnalogInV3.VoltageCallbackConfiguration BrickletAnalogInV3.getVoltageCallbackConfiguration()
Return Object:
  • period – Type: long, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • valueHasToChange – Type: boolean, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0
  • max – Type: int, Unit: 1 mV, Range: [0 to 216 - 1], Default: 0

Returns the listener configuration as set by setVoltageCallbackConfiguration().

The following constants are available for this function:

For option:

  • BrickletAnalogInV3.THRESHOLD_OPTION_OFF = 'x'
  • BrickletAnalogInV3.THRESHOLD_OPTION_OUTSIDE = 'o'
  • BrickletAnalogInV3.THRESHOLD_OPTION_INSIDE = 'i'
  • BrickletAnalogInV3.THRESHOLD_OPTION_SMALLER = '<'
  • BrickletAnalogInV3.THRESHOLD_OPTION_GREATER = '>'

Listeners

Listeners can be registered to receive time critical or recurring data from the device. The registration is done with add*Listener() functions of the device object.

The parameter is a listener class object, for example:

device.addExampleListener(new BrickletAnalogInV3.ExampleListener() {
    public void property(int value) {
        System.out.println("Value: " + value);
    }
});

The available listener classes with inherent methods to be overwritten are described below. It is possible to add several listeners and to remove them with the corresponding remove*Listener() function.

Note

Using listeners for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

class BrickletAnalogInV3.VoltageListener()

This listener can be added with the addVoltageListener() function. An added listener can be removed with the removeVoltageListener() function.

void voltage(int voltage)
Parameters:
  • voltage – Type: int, Unit: 1 mV, Range: [0 to 42000]

This listener is triggered periodically according to the configuration set by setVoltageCallbackConfiguration().

The parameter is the same as getVoltage().

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

short[] BrickletAnalogInV3.getAPIVersion()
Return Object:
  • apiVersion – Type: short[], Length: 3
    • 0: major – Type: short, Range: [0 to 255]
    • 1: minor – Type: short, Range: [0 to 255]
    • 2: revision – Type: short, Range: [0 to 255]

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

boolean BrickletAnalogInV3.getResponseExpected(byte functionId)
Parameters:
  • functionId – Type: byte, Range: See constants
Returns:
  • responseExpected – Type: boolean

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For listener configuration functions it is enabled by default too, but can be disabled by setResponseExpected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickletAnalogInV3.FUNCTION_SET_VOLTAGE_CALLBACK_CONFIGURATION = 2
  • BrickletAnalogInV3.FUNCTION_SET_OVERSAMPLING = 5
  • BrickletAnalogInV3.FUNCTION_SET_CALIBRATION = 7
  • BrickletAnalogInV3.FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • BrickletAnalogInV3.FUNCTION_SET_STATUS_LED_CONFIG = 239
  • BrickletAnalogInV3.FUNCTION_RESET = 243
  • BrickletAnalogInV3.FUNCTION_WRITE_UID = 248
void BrickletAnalogInV3.setResponseExpected(byte functionId, boolean responseExpected)
Parameters:
  • functionId – Type: byte, Range: See constants
  • responseExpected – Type: boolean

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and listener configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickletAnalogInV3.FUNCTION_SET_VOLTAGE_CALLBACK_CONFIGURATION = 2
  • BrickletAnalogInV3.FUNCTION_SET_OVERSAMPLING = 5
  • BrickletAnalogInV3.FUNCTION_SET_CALIBRATION = 7
  • BrickletAnalogInV3.FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • BrickletAnalogInV3.FUNCTION_SET_STATUS_LED_CONFIG = 239
  • BrickletAnalogInV3.FUNCTION_RESET = 243
  • BrickletAnalogInV3.FUNCTION_WRITE_UID = 248
void BrickletAnalogInV3.setResponseExpectedAll(boolean responseExpected)
Parameters:
  • responseExpected – Type: boolean

Changes the response expected flag for all setter and listener configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

int BrickletAnalogInV3.setBootloaderMode(int mode)
Parameters:
  • mode – Type: int, Range: See constants
Returns:
  • status – Type: int, Range: See constants

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following constants are available for this function:

For mode:

  • BrickletAnalogInV3.BOOTLOADER_MODE_BOOTLOADER = 0
  • BrickletAnalogInV3.BOOTLOADER_MODE_FIRMWARE = 1
  • BrickletAnalogInV3.BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • BrickletAnalogInV3.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • BrickletAnalogInV3.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4

For status:

  • BrickletAnalogInV3.BOOTLOADER_STATUS_OK = 0
  • BrickletAnalogInV3.BOOTLOADER_STATUS_INVALID_MODE = 1
  • BrickletAnalogInV3.BOOTLOADER_STATUS_NO_CHANGE = 2
  • BrickletAnalogInV3.BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT = 3
  • BrickletAnalogInV3.BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT = 4
  • BrickletAnalogInV3.BOOTLOADER_STATUS_CRC_MISMATCH = 5
int BrickletAnalogInV3.getBootloaderMode()
Returns:
  • mode – Type: int, Range: See constants

Returns the current bootloader mode, see setBootloaderMode().

The following constants are available for this function:

For mode:

  • BrickletAnalogInV3.BOOTLOADER_MODE_BOOTLOADER = 0
  • BrickletAnalogInV3.BOOTLOADER_MODE_FIRMWARE = 1
  • BrickletAnalogInV3.BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • BrickletAnalogInV3.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • BrickletAnalogInV3.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4
void BrickletAnalogInV3.setWriteFirmwarePointer(long pointer)
Parameters:
  • pointer – Type: long, Unit: 1 B, Range: [0 to 232 - 1]

Sets the firmware pointer for writeFirmware(). The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

int BrickletAnalogInV3.writeFirmware(int[] data)
Parameters:
  • data – Type: int[], Length: 64, Range: [0 to 255]
Returns:
  • status – Type: int, Range: [0 to 255]

Writes 64 Bytes of firmware at the position as written by setWriteFirmwarePointer() before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

void BrickletAnalogInV3.writeUID(long uid)
Parameters:
  • uid – Type: long, Range: [0 to 232 - 1]

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

long BrickletAnalogInV3.readUID()
Returns:
  • uid – Type: long, Range: [0 to 232 - 1]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Constants

int BrickletAnalogInV3.DEVICE_IDENTIFIER

This constant is used to identify a Analog In Bricklet 3.0.

The getIdentity() function and the IPConnection.EnumerateListener listener of the IP Connection have a deviceIdentifier parameter to specify the Brick's or Bricklet's type.

String BrickletAnalogInV3.DEVICE_DISPLAY_NAME

This constant represents the human readable name of a Analog In Bricklet 3.0.