This is the description of the Ruby API bindings for the Current25 Bricklet. General information and technical specifications for the Current25 Bricklet are summarized in its hardware description.
An installation guide for the Ruby API bindings is part of their general description.
The example code below is Public Domain (CC0 1.0).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 | #!/usr/bin/env ruby
# -*- ruby encoding: utf-8 -*-
require 'tinkerforge/ip_connection'
require 'tinkerforge/bricklet_current25'
include Tinkerforge
HOST = 'localhost'
PORT = 4223
UID = 'XYZ' # Change XYZ to the UID of your Current25 Bricklet
ipcon = IPConnection.new # Create IP connection
c = BrickletCurrent25.new UID, ipcon # Create device object
ipcon.connect HOST, PORT # Connect to brickd
# Don't use device before ipcon is connected
# Get current current
current = c.get_current
puts "Current: #{current/1000.0} A"
puts 'Press key to exit'
$stdin.gets
ipcon.disconnect
|
Download (example_callback.rb)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 | #!/usr/bin/env ruby
# -*- ruby encoding: utf-8 -*-
require 'tinkerforge/ip_connection'
require 'tinkerforge/bricklet_current25'
include Tinkerforge
HOST = 'localhost'
PORT = 4223
UID = 'XYZ' # Change XYZ to the UID of your Current25 Bricklet
ipcon = IPConnection.new # Create IP connection
c = BrickletCurrent25.new UID, ipcon # Create device object
ipcon.connect HOST, PORT # Connect to brickd
# Don't use device before ipcon is connected
# Register current callback
c.register_callback(BrickletCurrent25::CALLBACK_CURRENT) do |current|
puts "Current: #{current/1000.0} A"
end
# Set period for current callback to 1s (1000ms)
# Note: The current callback is only called every second
# if the current has changed since the last call!
c.set_current_callback_period 1000
puts 'Press key to exit'
$stdin.gets
ipcon.disconnect
|
Download (example_threshold.rb)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 | #!/usr/bin/env ruby
# -*- ruby encoding: utf-8 -*-
require 'tinkerforge/ip_connection'
require 'tinkerforge/bricklet_current25'
include Tinkerforge
HOST = 'localhost'
PORT = 4223
UID = 'XYZ' # Change XYZ to the UID of your Current25 Bricklet
ipcon = IPConnection.new # Create IP connection
c = BrickletCurrent25.new UID, ipcon # Create device object
ipcon.connect HOST, PORT # Connect to brickd
# Don't use device before ipcon is connected
# Get threshold callbacks with a debounce time of 10 seconds (10000ms)
c.set_debounce_period 10000
# Register current reached callback
c.register_callback(BrickletCurrent25::CALLBACK_CURRENT_REACHED) do |current|
puts "Current: #{current/1000.0} A"
end
# Configure threshold for current "greater than 5 A"
c.set_current_callback_threshold '>', 5*1000, 0
puts 'Press key to exit'
$stdin.gets
ipcon.disconnect
|
All functions listed below are thread-safe.
BrickletCurrent25
::
new
(uid, ipcon) → current25¶Parameters: |
|
---|---|
Returns: |
|
Creates an object with the unique device ID uid
:
current25 = BrickletCurrent25.new 'YOUR_DEVICE_UID', ipcon
This object can then be used after the IP Connection is connected.
BrickletCurrent25
#
get_current
→ int¶Returns: |
|
---|
Returns the current of the sensor.
If you want to get the current periodically, it is recommended to use the
::CALLBACK_CURRENT
callback and set the period with
#set_current_callback_period
.
BrickletCurrent25
#
calibrate
→ nil¶Calibrates the 0 value of the sensor. You have to call this function when there is no current present.
The zero point of the current sensor is depending on the exact properties of the analog-to-digital converter, the length of the Bricklet cable and the temperature. Thus, if you change the Brick or the environment in which the Bricklet is used, you might have to recalibrate.
The resulting calibration will be saved on the EEPROM of the Current Bricklet.
BrickletCurrent25
#
is_over_current
→ bool¶Returns: |
|
---|
Returns true if more than 25A were measured.
Note
To reset this value you have to power cycle the Bricklet.
BrickletCurrent25
#
get_analog_value
→ int¶Returns: |
|
---|
Returns the value as read by a 12-bit analog-to-digital converter.
Note
The value returned by #get_current
is averaged over several samples
to yield less noise, while #get_analog_value
gives back raw
unfiltered analog values. The only reason to use #get_analog_value
is,
if you need the full resolution of the analog-to-digital converter.
If you want the analog value periodically, it is recommended to use the
::CALLBACK_ANALOG_VALUE
callback and set the period with
#set_analog_value_callback_period
.
BrickletCurrent25
#
get_identity
→ [str, str, chr, [int, ...], [int, ...], int]¶Return Array: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.
BrickletCurrent25
#
register_callback
(callback_id) { |param [, ...]| block } → nil¶Parameters: |
|
---|
Registers the given block
with the given callback_id
.
The available callback IDs with corresponding function signatures are listed below.
BrickletCurrent25
#
set_current_callback_period
(period) → nil¶Parameters: |
|
---|
Sets the period with which the ::CALLBACK_CURRENT
callback is triggered
periodically. A value of 0 turns the callback off.
The ::CALLBACK_CURRENT
callback is only triggered if the current has changed since
the last triggering.
BrickletCurrent25
#
get_current_callback_period
→ int¶Returns: |
|
---|
Returns the period as set by #set_current_callback_period
.
BrickletCurrent25
#
set_analog_value_callback_period
(period) → nil¶Parameters: |
|
---|
Sets the period with which the ::CALLBACK_ANALOG_VALUE
callback is triggered
periodically. A value of 0 turns the callback off.
The ::CALLBACK_ANALOG_VALUE
callback is only triggered if the analog value has
changed since the last triggering.
BrickletCurrent25
#
get_analog_value_callback_period
→ int¶Returns: |
|
---|
Returns the period as set by #set_analog_value_callback_period
.
BrickletCurrent25
#
set_current_callback_threshold
(option, min, max) → nil¶Parameters: |
|
---|
Sets the thresholds for the ::CALLBACK_CURRENT_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the current is outside the min and max values |
'i' | Callback is triggered when the current is inside the min and max values |
'<' | Callback is triggered when the current is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the current is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletCurrent25
#
get_current_callback_threshold
→ [chr, int, int]¶Return Array: |
|
---|
Returns the threshold as set by #set_current_callback_threshold
.
The following constants are available for this function:
For option:
BrickletCurrent25
#
set_analog_value_callback_threshold
(option, min, max) → nil¶Parameters: |
|
---|
Sets the thresholds for the ::CALLBACK_ANALOG_VALUE_REACHED
callback.
The following options are possible:
Option | Description |
---|---|
'x' | Callback is turned off |
'o' | Callback is triggered when the analog value is outside the min and max values |
'i' | Callback is triggered when the analog value is inside the min and max values |
'<' | Callback is triggered when the analog value is smaller than the min value (max is ignored) |
'>' | Callback is triggered when the analog value is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletCurrent25
#
get_analog_value_callback_threshold
→ [chr, int, int]¶Return Array: |
|
---|
Returns the threshold as set by #set_analog_value_callback_threshold
.
The following constants are available for this function:
For option:
BrickletCurrent25
#
set_debounce_period
(debounce) → nil¶Parameters: |
|
---|
Sets the period with which the threshold callbacks
are triggered, if the thresholds
keep being reached.
BrickletCurrent25
#
get_debounce_period
→ int¶Returns: |
|
---|
Returns the debounce period as set by #set_debounce_period
.
Callbacks can be registered to receive time critical or recurring data from
the device. The registration is done with the
#register_callback
function of
the device object. The first parameter is the callback ID and the second
parameter is a block:
current25.register_callback BrickletCurrent25::CALLBACK_EXAMPLE, do |param|
puts "#{param}"
end
The available constants with inherent number and type of parameters are described below.
Note
Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.
BrickletCurrent25
::
CALLBACK_CURRENT
¶Callback Parameters: |
|
---|
This callback is triggered periodically with the period that is set by
#set_current_callback_period
. The parameter is the current of the
sensor.
The ::CALLBACK_CURRENT
callback is only triggered if the current has changed since the
last triggering.
BrickletCurrent25
::
CALLBACK_ANALOG_VALUE
¶Callback Parameters: |
|
---|
This callback is triggered periodically with the period that is set by
#set_analog_value_callback_period
. The parameter is the analog value of the
sensor.
The ::CALLBACK_ANALOG_VALUE
callback is only triggered if the current has changed since the
last triggering.
BrickletCurrent25
::
CALLBACK_CURRENT_REACHED
¶Callback Parameters: |
|
---|
This callback is triggered when the threshold as set by
#set_current_callback_threshold
is reached.
The parameter is the current of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by #set_debounce_period
.
BrickletCurrent25
::
CALLBACK_ANALOG_VALUE_REACHED
¶Callback Parameters: |
|
---|
This callback is triggered when the threshold as set by
#set_analog_value_callback_threshold
is reached.
The parameter is the analog value of the sensor.
If the threshold keeps being reached, the callback is triggered periodically
with the period as set by #set_debounce_period
.
BrickletCurrent25
::
CALLBACK_OVER_CURRENT
¶Callback Parameters: |
|
---|
This callback is triggered when an over current is measured
(see #is_over_current
).
Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.
BrickletCurrent25
#
get_api_version
→ [int, ...]¶Return Array: |
|
---|
Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
BrickletCurrent25
#
get_response_expected
(function_id) → bool¶Parameters: |
|
---|---|
Returns: |
|
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled,
because those functions will always send a response. For callback configuration
functions it is enabled by default too, but can be disabled by
#set_response_expected
. For setter functions it is disabled by default
and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For function_id:
BrickletCurrent25
#
set_response_expected
(function_id, response_expected) → nil¶Parameters: |
|
---|
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For function_id:
BrickletCurrent25
#
set_response_expected_all
(response_expected) → nil¶Parameters: |
|
---|
Changes the response expected flag for all setter and callback configuration functions of this device at once.
BrickletCurrent25
::
DEVICE_IDENTIFIER
¶This constant is used to identify a Current25 Bricklet.
The #get_identity()
function and the
IPConnection::CALLBACK_ENUMERATE
callback of the IP Connection have a device_identifier
parameter to specify
the Brick's or Bricklet's type.
BrickletCurrent25
::
DEVICE_DISPLAY_NAME
¶This constant represents the human readable name of a Current25 Bricklet.