This is the description of the Perl API bindings for the Industrial Analog Out Bricklet. General information and technical specifications for the Industrial Analog Out Bricklet are summarized in its hardware description.
An installation guide for the Perl API bindings is part of their general description.
The example code below is Public Domain (CC0 1.0).
Download (example_simple_current.pl)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 | #!/usr/bin/perl
use strict;
use Tinkerforge::IPConnection;
use Tinkerforge::BrickletIndustrialAnalogOut;
use constant HOST => 'localhost';
use constant PORT => 4223;
use constant UID => 'XYZ'; # Change XYZ to the UID of your Industrial Analog Out Bricklet
my $ipcon = Tinkerforge::IPConnection->new(); # Create IP connection
my $iao = Tinkerforge::BrickletIndustrialAnalogOut->new(&UID, $ipcon); # Create device object
$ipcon->connect(&HOST, &PORT); # Connect to brickd
# Don't use device before ipcon is connected
# Set output current to 4.5mA
$iao->set_current(4500);
$iao->enable();
print "Press key to exit\n";
<STDIN>;
$iao->disable();
$ipcon->disconnect();
|
Download (example_simple_voltage.pl)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 | #!/usr/bin/perl
use strict;
use Tinkerforge::IPConnection;
use Tinkerforge::BrickletIndustrialAnalogOut;
use constant HOST => 'localhost';
use constant PORT => 4223;
use constant UID => 'XYZ'; # Change XYZ to the UID of your Industrial Analog Out Bricklet
my $ipcon = Tinkerforge::IPConnection->new(); # Create IP connection
my $iao = Tinkerforge::BrickletIndustrialAnalogOut->new(&UID, $ipcon); # Create device object
$ipcon->connect(&HOST, &PORT); # Connect to brickd
# Don't use device before ipcon is connected
# Set output voltage to 3.3V
$iao->set_voltage(3300);
$iao->enable();
print "Press key to exit\n";
<STDIN>;
$iao->disable();
$ipcon->disconnect();
|
Generally, every subroutine of the Perl bindings can report an error as
Tinkerforge::Error
object via croak()
. The object has a
get_code()
and a get_message()
subroutine. There are different
error code:
All functions listed below are thread-safe.
BrickletIndustrialAnalogOut
->
new
($uid, $ipcon)¶Parameters: |
|
---|---|
Returns: |
|
Creates an object with the unique device ID $uid
:
$industrial_analog_out = BrickletIndustrialAnalogOut->new("YOUR_DEVICE_UID", $ipcon);
This object can then be used after the IP Connection is connected.
BrickletIndustrialAnalogOut
->
enable
()¶Returns: |
|
---|
Enables the output of voltage and current.
The default is disabled.
BrickletIndustrialAnalogOut
->
disable
()¶Returns: |
|
---|
Disables the output of voltage and current.
The default is disabled.
BrickletIndustrialAnalogOut
->
is_enabled
()¶Returns: |
|
---|
Returns true if output of voltage and current is enabled, false otherwise.
BrickletIndustrialAnalogOut
->
set_voltage
($voltage)¶Parameters: |
|
---|---|
Returns: |
|
Sets the output voltage.
The output voltage and output current are linked. Changing the output voltage also changes the output current.
BrickletIndustrialAnalogOut
->
get_voltage
()¶Returns: |
|
---|
Returns the voltage as set by set_voltage()
.
BrickletIndustrialAnalogOut
->
set_current
($current)¶Parameters: |
|
---|---|
Returns: |
|
Sets the output current.
The output current and output voltage are linked. Changing the output current also changes the output voltage.
BrickletIndustrialAnalogOut
->
get_current
()¶Returns: |
|
---|
Returns the current as set by set_current()
.
BrickletIndustrialAnalogOut
->
set_configuration
($voltage_range, $current_range)¶Parameters: |
|
---|---|
Returns: |
|
Configures the voltage and current range.
Possible voltage ranges are:
Possible current ranges are:
The resolution will always be 12 bit. This means, that the precision is higher with a smaller range.
The following constants are available for this function:
For $voltage_range:
For $current_range:
BrickletIndustrialAnalogOut
->
get_configuration
()¶Return Array: |
|
---|
Returns the configuration as set by set_configuration()
.
The following constants are available for this function:
For $voltage_range:
For $current_range:
BrickletIndustrialAnalogOut
->
get_identity
()¶Return Array: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.
Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.
BrickletIndustrialAnalogOut
->
get_api_version
()¶Return Array: |
|
---|
Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
BrickletIndustrialAnalogOut
->
get_response_expected
($function_id)¶Parameters: |
|
---|---|
Returns: |
|
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled,
because those functions will always send a response. For callback configuration
functions it is enabled by default too, but can be disabled by
set_response_expected()
. For setter functions it is disabled by default
and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For $function_id:
BrickletIndustrialAnalogOut
->
set_response_expected
($function_id, $response_expected)¶Parameters: |
|
---|---|
Returns: |
|
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For $function_id:
BrickletIndustrialAnalogOut
->
set_response_expected_all
($response_expected)¶Parameters: |
|
---|---|
Returns: |
|
Changes the response expected flag for all setter and callback configuration functions of this device at once.
BrickletIndustrialAnalogOut
->
DEVICE_IDENTIFIER
¶This constant is used to identify a Industrial Analog Out Bricklet.
The get_identity()
function and the
IPConnection->CALLBACK_ENUMERATE
callback of the IP Connection have a device_identifier
parameter to specify
the Brick's or Bricklet's type.
BrickletIndustrialAnalogOut
->
DEVICE_DISPLAY_NAME
¶This constant represents the human readable name of a Industrial Analog Out Bricklet.