C# - Motion Detector Bricklet 2.0

This is the description of the C# API bindings for the Motion Detector Bricklet 2.0. General information and technical specifications for the Motion Detector Bricklet 2.0 are summarized in its hardware description.

An installation guide for the C# API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Indicator

Download (ExampleIndicator.cs)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
using System;
using Tinkerforge;

class Example
{
    private static string HOST = "localhost";
    private static int PORT = 4223;
    private static string UID = "XYZ"; // Change XYZ to the UID of your Motion Detector Bricklet 2.0

    static void Main()
    {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletMotionDetectorV2 md =
          new BrickletMotionDetectorV2(UID, ipcon); // Create device object

        ipcon.Connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Turn blue backlight LEDs on (maximum brightness)
        md.SetIndicator(255, 255, 255);

        Console.WriteLine("Press enter to exit");
        Console.ReadLine();
        ipcon.Disconnect();
    }
}

Callback

Download (ExampleCallback.cs)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
using System;
using Tinkerforge;

class Example
{
    private static string HOST = "localhost";
    private static int PORT = 4223;
    private static string UID = "XYZ"; // Change XYZ to the UID of your Motion Detector Bricklet 2.0

    // Callback function for motion detected callback
    static void MotionDetectedCB(BrickletMotionDetectorV2 sender)
    {
        Console.WriteLine("Motion Detected");
    }

    // Callback function for detection cycle ended callback
    static void DetectionCycleEndedCB(BrickletMotionDetectorV2 sender)
    {
        Console.WriteLine("Detection Cycle Ended (next detection possible in ~2 seconds)");
    }

    static void Main()
    {
        IPConnection ipcon = new IPConnection(); // Create IP connection
        BrickletMotionDetectorV2 md =
          new BrickletMotionDetectorV2(UID, ipcon); // Create device object

        ipcon.Connect(HOST, PORT); // Connect to brickd
        // Don't use device before ipcon is connected

        // Register motion detected callback to function MotionDetectedCB
        md.MotionDetectedCallback += MotionDetectedCB;

        // Register detection cycle ended callback to function DetectionCycleEndedCB
        md.DetectionCycleEndedCallback += DetectionCycleEndedCB;

        Console.WriteLine("Press enter to exit");
        Console.ReadLine();
        ipcon.Disconnect();
    }
}

API

Generally, every method of the C# bindings that returns a value can throw a Tinkerforge.TimeoutException. This exception gets thrown if the device did not respond. If a cable based connection is used, it is unlikely that this exception gets thrown (assuming nobody plugs the device out). However, if a wireless connection is used, timeouts will occur if the distance to the device gets too big.

Since C# does not support multiple return values directly, we use the out keyword to return multiple values from a method.

The namespace for all Brick/Bricklet bindings and the IPConnection is Tinkerforge.*.

All methods listed below are thread-safe.

Basic Functions

class BrickletMotionDetectorV2(string uid, IPConnection ipcon)
Parameters:
  • uid – Type: string
  • ipcon – Type: IPConnection
Returns:
  • motionDetectorV2 – Type: BrickletMotionDetectorV2

Creates an object with the unique device ID uid:

BrickletMotionDetectorV2 motionDetectorV2 = new BrickletMotionDetectorV2("YOUR_DEVICE_UID", ipcon);

This object can then be used after the IP Connection is connected.

byte BrickletMotionDetectorV2.GetMotionDetected()
Returns:
  • motion – Type: byte, Range: See constants

Returns 1 if a motion was detected. It returns 1 approx. for 1.8 seconds until the sensor checks for a new movement.

The following constants are available for this function:

For motion:

  • BrickletMotionDetectorV2.MOTION_NOT_DETECTED = 0
  • BrickletMotionDetectorV2.MOTION_DETECTED = 1
void BrickletMotionDetectorV2.SetSensitivity(byte sensitivity)
Parameters:
  • sensitivity – Type: byte, Range: [0 to 100], Default: 50

Sets the sensitivity of the PIR sensor. At full sensitivity (100), the Bricklet can detect motion in a range of approximately 12m.

The actual range depends on many things in the environment (e.g. reflections) and the size of the object to be detected. While a big person might be detected in a range of 10m a cat may only be detected at 2m distance with the same setting.

So you will have to find a good sensitivity for your application by trial and error.

byte BrickletMotionDetectorV2.GetSensitivity()
Returns:
  • sensitivity – Type: byte, Range: [0 to 100], Default: 50

Returns the sensitivity as set by SetSensitivity().

void BrickletMotionDetectorV2.SetIndicator(byte topLeft, byte topRight, byte bottom)
Parameters:
  • topLeft – Type: byte, Range: [0 to 255], Default: 0
  • topRight – Type: byte, Range: [0 to 255], Default: 0
  • bottom – Type: byte, Range: [0 to 255], Default: 0

Sets the blue backlight of the fresnel lens. The backlight consists of three LEDs. The brightness of each LED can be controlled with a 8-bit value (0-255). A value of 0 turns the LED off and a value of 255 turns the LED to full brightness.

void BrickletMotionDetectorV2.GetIndicator(out byte topLeft, out byte topRight, out byte bottom)
Output Parameters:
  • topLeft – Type: byte, Range: [0 to 255], Default: 0
  • topRight – Type: byte, Range: [0 to 255], Default: 0
  • bottom – Type: byte, Range: [0 to 255], Default: 0

Returns the indicator configuration as set by SetIndicator().

Advanced Functions

void BrickletMotionDetectorV2.GetSPITFPErrorCount(out long errorCountAckChecksum, out long errorCountMessageChecksum, out long errorCountFrame, out long errorCountOverflow)
Output Parameters:
  • errorCountAckChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountMessageChecksum – Type: long, Range: [0 to 232 - 1]
  • errorCountFrame – Type: long, Range: [0 to 232 - 1]
  • errorCountOverflow – Type: long, Range: [0 to 232 - 1]

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

void BrickletMotionDetectorV2.SetStatusLEDConfig(byte config)
Parameters:
  • config – Type: byte, Range: See constants, Default: 3

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following constants are available for this function:

For config:

  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_OFF = 0
  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_ON = 1
  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_SHOW_STATUS = 3
byte BrickletMotionDetectorV2.GetStatusLEDConfig()
Returns:
  • config – Type: byte, Range: See constants, Default: 3

Returns the configuration as set by SetStatusLEDConfig()

The following constants are available for this function:

For config:

  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_OFF = 0
  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_ON = 1
  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • BrickletMotionDetectorV2.STATUS_LED_CONFIG_SHOW_STATUS = 3
short BrickletMotionDetectorV2.GetChipTemperature()
Returns:
  • temperature – Type: short, Unit: 1 °C, Range: [-215 to 215 - 1]

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

void BrickletMotionDetectorV2.Reset()

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

void BrickletMotionDetectorV2.GetIdentity(out string uid, out string connectedUid, out char position, out byte[] hardwareVersion, out byte[] firmwareVersion, out int deviceIdentifier)
Output Parameters:
  • uid – Type: string, Length: up to 8
  • connectedUid – Type: string, Length: up to 8
  • position – Type: char, Range: ['a' to 'h', 'z']
  • hardwareVersion – Type: byte[], Length: 3
    • 0: major – Type: byte, Range: [0 to 255]
    • 1: minor – Type: byte, Range: [0 to 255]
    • 2: revision – Type: byte, Range: [0 to 255]
  • firmwareVersion – Type: byte[], Length: 3
    • 0: major – Type: byte, Range: [0 to 255]
    • 1: minor – Type: byte, Range: [0 to 255]
    • 2: revision – Type: byte, Range: [0 to 255]
  • deviceIdentifier – Type: int, Range: [0 to 216 - 1]

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done by appending your callback handler to the corresponding event:

void MyCallback(BrickletMotionDetectorV2 sender, int value)
{
    System.Console.WriteLine("Value: " + value);
}

motionDetectorV2.ExampleCallback += MyCallback;

The available events are described below.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

event BrickletMotionDetectorV2.MotionDetectedCallback(BrickletMotionDetectorV2 sender)
Callback Parameters:
  • sender – Type: BrickletMotionDetectorV2

This callback is called after a motion was detected.

event BrickletMotionDetectorV2.DetectionCycleEndedCallback(BrickletMotionDetectorV2 sender)
Callback Parameters:
  • sender – Type: BrickletMotionDetectorV2

This callback is called when the detection cycle ended. When this callback is called, a new motion can be detected again after approximately 2 seconds.

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

byte[] BrickletMotionDetectorV2.GetAPIVersion()
Output Parameters:
  • apiVersion – Type: byte[], Length: 3
    • 0: major – Type: byte, Range: [0 to 255]
    • 1: minor – Type: byte, Range: [0 to 255]
    • 2: revision – Type: byte, Range: [0 to 255]

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

bool BrickletMotionDetectorV2.GetResponseExpected(byte functionId)
Parameters:
  • functionId – Type: byte, Range: See constants
Returns:
  • responseExpected – Type: bool

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by SetResponseExpected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickletMotionDetectorV2.FUNCTION_SET_SENSITIVITY = 2
  • BrickletMotionDetectorV2.FUNCTION_SET_INDICATOR = 4
  • BrickletMotionDetectorV2.FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • BrickletMotionDetectorV2.FUNCTION_SET_STATUS_LED_CONFIG = 239
  • BrickletMotionDetectorV2.FUNCTION_RESET = 243
  • BrickletMotionDetectorV2.FUNCTION_WRITE_UID = 248
void BrickletMotionDetectorV2.SetResponseExpected(byte functionId, bool responseExpected)
Parameters:
  • functionId – Type: byte, Range: See constants
  • responseExpected – Type: bool

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For functionId:

  • BrickletMotionDetectorV2.FUNCTION_SET_SENSITIVITY = 2
  • BrickletMotionDetectorV2.FUNCTION_SET_INDICATOR = 4
  • BrickletMotionDetectorV2.FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • BrickletMotionDetectorV2.FUNCTION_SET_STATUS_LED_CONFIG = 239
  • BrickletMotionDetectorV2.FUNCTION_RESET = 243
  • BrickletMotionDetectorV2.FUNCTION_WRITE_UID = 248
void BrickletMotionDetectorV2.SetResponseExpectedAll(bool responseExpected)
Parameters:
  • responseExpected – Type: bool

Changes the response expected flag for all setter and callback configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

byte BrickletMotionDetectorV2.SetBootloaderMode(byte mode)
Parameters:
  • mode – Type: byte, Range: See constants
Returns:
  • status – Type: byte, Range: See constants

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following constants are available for this function:

For mode:

  • BrickletMotionDetectorV2.BOOTLOADER_MODE_BOOTLOADER = 0
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_FIRMWARE = 1
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4

For status:

  • BrickletMotionDetectorV2.BOOTLOADER_STATUS_OK = 0
  • BrickletMotionDetectorV2.BOOTLOADER_STATUS_INVALID_MODE = 1
  • BrickletMotionDetectorV2.BOOTLOADER_STATUS_NO_CHANGE = 2
  • BrickletMotionDetectorV2.BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT = 3
  • BrickletMotionDetectorV2.BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT = 4
  • BrickletMotionDetectorV2.BOOTLOADER_STATUS_CRC_MISMATCH = 5
byte BrickletMotionDetectorV2.GetBootloaderMode()
Returns:
  • mode – Type: byte, Range: See constants

Returns the current bootloader mode, see SetBootloaderMode().

The following constants are available for this function:

For mode:

  • BrickletMotionDetectorV2.BOOTLOADER_MODE_BOOTLOADER = 0
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_FIRMWARE = 1
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • BrickletMotionDetectorV2.BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4
void BrickletMotionDetectorV2.SetWriteFirmwarePointer(long pointer)
Parameters:
  • pointer – Type: long, Unit: 1 B, Range: [0 to 232 - 1]

Sets the firmware pointer for WriteFirmware(). The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

byte BrickletMotionDetectorV2.WriteFirmware(byte[] data)
Parameters:
  • data – Type: byte[], Length: 64, Range: [0 to 255]
Returns:
  • status – Type: byte, Range: [0 to 255]

Writes 64 Bytes of firmware at the position as written by SetWriteFirmwarePointer() before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

void BrickletMotionDetectorV2.WriteUID(long uid)
Parameters:
  • uid – Type: long, Range: [0 to 232 - 1]

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

long BrickletMotionDetectorV2.ReadUID()
Returns:
  • uid – Type: long, Range: [0 to 232 - 1]

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Constants

int BrickletMotionDetectorV2.DEVICE_IDENTIFIER

This constant is used to identify a Motion Detector Bricklet 2.0.

The GetIdentity() function and the IPConnection.EnumerateCallback callback of the IP Connection have a deviceIdentifier parameter to specify the Brick's or Bricklet's type.

string BrickletMotionDetectorV2.DEVICE_DISPLAY_NAME

This constant represents the human readable name of a Motion Detector Bricklet 2.0.