This is the description of the openHAB API bindings for the Current25 Bricklet. General information and technical specifications for the Current25 Bricklet are summarized in its hardware description.
An installation guide for the openHAB API bindings is part of their general description.
UID:
- tinkerforge:brickletcurrent25:[UID]
Required firmware version:
- 2.0.0
Firmware update supported:
- yes
Channels: Actions:
Current
¶The measured current.
Type:
- Number:ElectricCurrent
UID:
- tinkerforge:brickletcurrent25:[UID]:BrickletCurrent25Current
Read only:
- Yes
Unit:
- Ampere
Range:
- -25 Ampere to 25 Ampere (Step 0.001 Ampere)
Parameters:
- Update Interval – Type: integer, Default: 1000, Unit: ms, Min: 0, Max: 4294967295
- Specifies the update interval in milliseconds. A value of 0 disables automatic updates.
Over Current
¶Enabled if more than 25A were measured. To reset this value you have to power cycle the Bricklet.
Type:
- Contact
UID:
- tinkerforge:brickletcurrent25:[UID]:BrickletCurrent25OverCurrent
Read only:
- No
Analog Value
¶Returns the value as read by a 12-bit analog-to-digital converter.
Bemerkung
The value returned by Get Current()
is averaged over several samples
to yield less noise, while Get Analog Value()
gives back raw
unfiltered analog values. The only reason to use Get Analog Value()
is,
if you need the full resolution of the analog-to-digital converter.
Type: |
|
---|---|
UID: |
|
Read only: |
|
Range: |
|
Parameters: |
|
Actions can be used in rules by creating an action object. All actions return a Map<String, Object>. Returned values can be accessed by name, sometimes the type deduction needs some hints, as shown below:
val actions = getActions("tinkerforge", "tinkerforge:brickletcurrent25:[UID]")
val hwVersion = actions.brickletCurrent25GetIdentity().get("hardwareVersion") as short[]
logInfo("Example", "Hardware version: " + hwVersion.get(0) + "." + hwVersion.get(1) + "." + hwVersion.get(2))
brickletCurrent25IsOverCurrent
()¶Return Map: |
|
---|
Returns true if more than 25A were measured.
Bemerkung
To reset this value you have to power cycle the Bricklet.
brickletCurrent25GetAnalogValue
()¶Return Map: |
|
---|
Returns the value as read by a 12-bit analog-to-digital converter.
Bemerkung
The value returned by Current
is averaged over several samples
to yield less noise, while Analog Value
gives back raw
unfiltered analog values. The only reason to use Analog Value
is,
if you need the full resolution of the analog-to-digital converter.
If you want the analog value periodically, it is recommended to use the
Analog Value
channel and set the period with
the configuration of Analog Value
.
brickletCurrent25GetIdentity
()¶Return Map: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here.