This is the description of the Java API bindings for the Analog In Bricklet 2.0. General information and technical specifications for the Analog In Bricklet 2.0 are summarized in its hardware description.
An installation guide for the Java API bindings is part of their general description.
The example code below is Public Domain (CC0 1.0).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 | import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletAnalogInV2;
public class ExampleSimple {
private static final String HOST = "localhost";
private static final int PORT = 4223;
// Change XYZ to the UID of your Analog In Bricklet 2.0
private static final String UID = "XYZ";
// Note: To make the example code cleaner we do not handle exceptions. Exceptions
// you might normally want to catch are described in the documentation
public static void main(String args[]) throws Exception {
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletAnalogInV2 ai = new BrickletAnalogInV2(UID, ipcon); // Create device object
ipcon.connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Get current voltage
int voltage = ai.getVoltage(); // Can throw com.tinkerforge.TimeoutException
System.out.println("Voltage: " + voltage/1000.0 + " V");
System.out.println("Press key to exit"); System.in.read();
ipcon.disconnect();
}
}
|
Download (ExampleCallback.java)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 | import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletAnalogInV2;
public class ExampleCallback {
private static final String HOST = "localhost";
private static final int PORT = 4223;
// Change XYZ to the UID of your Analog In Bricklet 2.0
private static final String UID = "XYZ";
// Note: To make the example code cleaner we do not handle exceptions. Exceptions
// you might normally want to catch are described in the documentation
public static void main(String args[]) throws Exception {
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletAnalogInV2 ai = new BrickletAnalogInV2(UID, ipcon); // Create device object
ipcon.connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Add voltage listener
ai.addVoltageListener(new BrickletAnalogInV2.VoltageListener() {
public void voltage(int voltage) {
System.out.println("Voltage: " + voltage/1000.0 + " V");
}
});
// Set period for voltage callback to 1s (1000ms)
// Note: The voltage callback is only called every second
// if the voltage has changed since the last call!
ai.setVoltageCallbackPeriod(1000);
System.out.println("Press key to exit"); System.in.read();
ipcon.disconnect();
}
}
|
Download (ExampleThreshold.java)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 | import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletAnalogInV2;
public class ExampleThreshold {
private static final String HOST = "localhost";
private static final int PORT = 4223;
// Change XYZ to the UID of your Analog In Bricklet 2.0
private static final String UID = "XYZ";
// Note: To make the example code cleaner we do not handle exceptions. Exceptions
// you might normally want to catch are described in the documentation
public static void main(String args[]) throws Exception {
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletAnalogInV2 ai = new BrickletAnalogInV2(UID, ipcon); // Create device object
ipcon.connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Get threshold callbacks with a debounce time of 10 seconds (10000ms)
ai.setDebouncePeriod(10000);
// Add voltage reached listener
ai.addVoltageReachedListener(new BrickletAnalogInV2.VoltageReachedListener() {
public void voltageReached(int voltage) {
System.out.println("Voltage: " + voltage/1000.0 + " V");
}
});
// Configure threshold for voltage "smaller than 5 V"
ai.setVoltageCallbackThreshold('<', 5*1000, 0);
System.out.println("Press key to exit"); System.in.read();
ipcon.disconnect();
}
}
|
Generally, every method of the Java bindings that returns a value can
throw a TimeoutException
. This exception gets thrown if the
device did not respond. If a cable based connection is used, it is
unlikely that this exception gets thrown (assuming nobody unplugs the
device). However, if a wireless connection is used, timeouts will occur
if the distance to the device gets too big.
Beside the TimeoutException
there is also a NotConnectedException
that
is thrown if a method needs to communicate with the device while the
IP Connection is not connected.
Since Java does not support multiple return values and return by reference is not possible for primitive types, we use small classes that only consist of member variables. The member variables of the returned objects are described in the corresponding method descriptions.
The package for all Brick/Bricklet bindings and the IP Connection is
com.tinkerforge.*
All methods listed below are thread-safe.
BrickletAnalogInV2
(String uid, IPConnection ipcon)¶Parameters: |
|
---|---|
Returns: |
|
Creates an object with the unique device ID uid
:
BrickletAnalogInV2 analogInV2 = new BrickletAnalogInV2("YOUR_DEVICE_UID", ipcon);
This object can then be used after the IP Connection is connected.
BrickletAnalogInV2.
getVoltage
()¶Returns: |
|
---|
Returns the measured voltage. The resolution is approximately 10mV.
If you want to get the voltage periodically, it is recommended to use the
VoltageListener
listener and set the period with
setVoltageCallbackPeriod()
.
BrickletAnalogInV2.
getAnalogValue
()¶Returns: |
|
---|
Returns the value as read by a 12-bit analog-to-digital converter.
If you want the analog value periodically, it is recommended to use the
AnalogValueListener
listener and set the period with
setAnalogValueCallbackPeriod()
.
BrickletAnalogInV2.
setMovingAverage
(short average)¶Parameters: |
|
---|
Sets the length of a moving averaging for the voltage.
Setting the length to 1 will turn the averaging off. With less averaging, there is more noise on the data.
BrickletAnalogInV2.
getMovingAverage
()¶Returns: |
|
---|
Returns the length of the moving average as set by setMovingAverage()
.
BrickletAnalogInV2.
getIdentity
()¶Return Object: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.
BrickletAnalogInV2.
setVoltageCallbackPeriod
(long period)¶Parameters: |
|
---|
Sets the period with which the VoltageListener
listener is triggered
periodically. A value of 0 turns the listener off.
The VoltageListener
listener is only triggered if the voltage has changed since
the last triggering.
BrickletAnalogInV2.
getVoltageCallbackPeriod
()¶Returns: |
|
---|
Returns the period as set by setVoltageCallbackPeriod()
.
BrickletAnalogInV2.
setAnalogValueCallbackPeriod
(long period)¶Parameters: |
|
---|
Sets the period with which the AnalogValueListener
listener is triggered
periodically. A value of 0 turns the listener off.
The AnalogValueListener
listener is only triggered if the analog value has
changed since the last triggering.
BrickletAnalogInV2.
getAnalogValueCallbackPeriod
()¶Returns: |
|
---|
Returns the period as set by setAnalogValueCallbackPeriod()
.
BrickletAnalogInV2.
setVoltageCallbackThreshold
(char option, int min, int max)¶Parameters: |
|
---|
Sets the thresholds for the VoltageReachedListener
listener.
The following options are possible:
Option | Description |
---|---|
'x' | Listener is turned off |
'o' | Listener is triggered when the voltage is outside the min and max values |
'i' | Listener is triggered when the voltage is inside the min and max values |
'<' | Listener is triggered when the voltage is smaller than the min value (max is ignored) |
'>' | Listener is triggered when the voltage is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletAnalogInV2.
getVoltageCallbackThreshold
()¶Return Object: |
|
---|
Returns the threshold as set by setVoltageCallbackThreshold()
.
The following constants are available for this function:
For option:
BrickletAnalogInV2.
setAnalogValueCallbackThreshold
(char option, int min, int max)¶Parameters: |
|
---|
Sets the thresholds for the AnalogValueReachedListener
listener.
The following options are possible:
Option | Description |
---|---|
'x' | Listener is turned off |
'o' | Listener is triggered when the analog value is outside the min and max values |
'i' | Listener is triggered when the analog value is inside the min and max values |
'<' | Listener is triggered when the analog value is smaller than the min value (max is ignored) |
'>' | Listener is triggered when the analog value is greater than the min value (max is ignored) |
The following constants are available for this function:
For option:
BrickletAnalogInV2.
getAnalogValueCallbackThreshold
()¶Return Object: |
|
---|
Returns the threshold as set by setAnalogValueCallbackThreshold()
.
The following constants are available for this function:
For option:
BrickletAnalogInV2.
setDebouncePeriod
(long debounce)¶Parameters: |
|
---|
Sets the period with which the threshold listeners
are triggered, if the thresholds
keep being reached.
BrickletAnalogInV2.
getDebouncePeriod
()¶Returns: |
|
---|
Returns the debounce period as set by setDebouncePeriod()
.
Listeners can be registered to receive
time critical or recurring data from the device. The registration is done
with add*Listener()
functions of the device object.
The parameter is a listener class object, for example:
device.addExampleListener(new BrickletAnalogInV2.ExampleListener() {
public void property(int value) {
System.out.println("Value: " + value);
}
});
The available listener classes with inherent methods to be overwritten
are described below. It is possible to add several listeners and
to remove them with the corresponding remove*Listener()
function.
Note
Using listeners for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.
BrickletAnalogInV2.
VoltageListener
()¶This listener can be added with the addVoltageListener()
function.
An added listener can be removed with the removeVoltageListener()
function.
voltage
(int voltage)Parameters: |
|
---|
This listener is triggered periodically with the period that is set by
setVoltageCallbackPeriod()
. The parameter is the voltage of the
sensor.
Der VoltageListener
listener is only triggered if the voltage has changed since
the last triggering.
BrickletAnalogInV2.
AnalogValueListener
()¶This listener can be added with the addAnalogValueListener()
function.
An added listener can be removed with the removeAnalogValueListener()
function.
analogValue
(int value)Parameters: |
|
---|
This listener is triggered periodically with the period that is set by
setAnalogValueCallbackPeriod()
. The parameter is the analog
value of the sensor.
The AnalogValueListener
listener is only triggered if the voltage has changed
since the last triggering.
BrickletAnalogInV2.
VoltageReachedListener
()¶This listener can be added with the addVoltageReachedListener()
function.
An added listener can be removed with the removeVoltageReachedListener()
function.
voltageReached
(int voltage)Parameters: |
|
---|
This listener is triggered when the threshold as set by
setVoltageCallbackThreshold()
is reached.
The parameter is the voltage of the sensor.
If the threshold keeps being reached, the listener is triggered periodically
with the period as set by setDebouncePeriod()
.
BrickletAnalogInV2.
AnalogValueReachedListener
()¶This listener can be added with the addAnalogValueReachedListener()
function.
An added listener can be removed with the removeAnalogValueReachedListener()
function.
analogValueReached
(int value)Parameters: |
|
---|
This listener is triggered when the threshold as set by
setAnalogValueCallbackThreshold()
is reached.
The parameter is the analog value of the sensor.
If the threshold keeps being reached, the listener is triggered periodically
with the period as set by setDebouncePeriod()
.
Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.
BrickletAnalogInV2.
getAPIVersion
()¶Return Object: |
|
---|
Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
BrickletAnalogInV2.
getResponseExpected
(byte functionId)¶Parameters: |
|
---|---|
Returns: |
|
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled,
because those functions will always send a response. For listener configuration
functions it is enabled by default too, but can be disabled by
setResponseExpected()
. For setter functions it is disabled by default
and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletAnalogInV2.
setResponseExpected
(byte functionId, boolean responseExpected)¶Parameters: |
|
---|
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and listener configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletAnalogInV2.
setResponseExpectedAll
(boolean responseExpected)¶Parameters: |
|
---|
Changes the response expected flag for all setter and listener configuration functions of this device at once.
BrickletAnalogInV2.
DEVICE_IDENTIFIER
¶This constant is used to identify a Analog In Bricklet 2.0.
The getIdentity()
function and the
IPConnection.EnumerateListener
listener of the IP Connection have a deviceIdentifier
parameter to specify
the Brick's or Bricklet's type.
BrickletAnalogInV2.
DEVICE_DISPLAY_NAME
¶This constant represents the human readable name of a Analog In Bricklet 2.0.