This is the description of the Java API bindings for the Dual Relay Bricklet. General information and technical specifications for the Dual Relay Bricklet are summarized in its hardware description.
An installation guide for the Java API bindings is part of their general description.
The example code below is Public Domain (CC0 1.0).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 | import com.tinkerforge.IPConnection;
import com.tinkerforge.BrickletDualRelay;
public class ExampleSimple {
private static final String HOST = "localhost";
private static final int PORT = 4223;
// Change XYZ to the UID of your Dual Relay Bricklet
private static final String UID = "XYZ";
// Note: To make the example code cleaner we do not handle exceptions. Exceptions
// you might normally want to catch are described in the documentation
public static void main(String args[]) throws Exception {
IPConnection ipcon = new IPConnection(); // Create IP connection
BrickletDualRelay dr = new BrickletDualRelay(UID, ipcon); // Create device object
ipcon.connect(HOST, PORT); // Connect to brickd
// Don't use device before ipcon is connected
// Turn relays alternating on/off 10 times with 1 second delay
for(int i = 0; i < 5; i++) {
Thread.sleep(1000);
dr.setState(true, false);
Thread.sleep(1000);
dr.setState(false, true);
}
System.out.println("Press key to exit"); System.in.read();
ipcon.disconnect();
}
}
|
Generally, every method of the Java bindings that returns a value can
throw a TimeoutException
. This exception gets thrown if the
device did not respond. If a cable based connection is used, it is
unlikely that this exception gets thrown (assuming nobody unplugs the
device). However, if a wireless connection is used, timeouts will occur
if the distance to the device gets too big.
Beside the TimeoutException
there is also a NotConnectedException
that
is thrown if a method needs to communicate with the device while the
IP Connection is not connected.
Since Java does not support multiple return values and return by reference is not possible for primitive types, we use small classes that only consist of member variables. The member variables of the returned objects are described in the corresponding method descriptions.
The package for all Brick/Bricklet bindings and the IP Connection is
com.tinkerforge.*
All methods listed below are thread-safe.
BrickletDualRelay
(String uid, IPConnection ipcon)¶Parameters: |
|
---|---|
Returns: |
|
Creates an object with the unique device ID uid
:
BrickletDualRelay dualRelay = new BrickletDualRelay("YOUR_DEVICE_UID", ipcon);
This object can then be used after the IP Connection is connected.
BrickletDualRelay.
setState
(boolean relay1, boolean relay2)¶Parameters: |
|
---|
Sets the state of the relays, true means on and false means off. For example: (true, false) turns relay 1 on and relay 2 off.
If you just want to set one of the relays and don't know the current state
of the other relay, you can get the state with getState()
or you
can use setSelectedState()
.
All running monoflop timers will be aborted if this function is called.
BrickletDualRelay.
getState
()¶Return Object: |
|
---|
Returns the state of the relays, true means on and false means off.
BrickletDualRelay.
setMonoflop
(short relay, boolean state, long time)¶Parameters: |
|
---|
The first parameter can be 1 or 2 (relay 1 or relay 2). The second parameter is the desired state of the relay (true means on and false means off). The third parameter indicates the time that the relay should hold the state.
If this function is called with the parameters (1, true, 1500): Relay 1 will turn on and in 1.5s it will turn off again.
A monoflop can be used as a failsafe mechanism. For example: Lets assume you have a RS485 bus and a Dual Relay Bricklet connected to one of the slave stacks. You can now call this function every second, with a time parameter of two seconds. The relay will be on all the time. If now the RS485 connection is lost, the relay will turn off in at most two seconds.
BrickletDualRelay.
getMonoflop
(short relay)¶Parameters: |
|
---|---|
Return Object: |
|
Returns (for the given relay) the current state and the time as set by
setMonoflop()
as well as the remaining time until the state flips.
If the timer is not running currently, the remaining time will be returned as 0.
BrickletDualRelay.
setSelectedState
(short relay, boolean state)¶Parameters: |
|
---|
Sets the state of the selected relay (1 or 2), true means on and false means off.
A running monoflop timer for the selected relay will be aborted if this function is called.
The other relay remains untouched.
BrickletDualRelay.
getIdentity
()¶Return Object: |
|
---|
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.
The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.
Listeners can be registered to receive
time critical or recurring data from the device. The registration is done
with add*Listener()
functions of the device object.
The parameter is a listener class object, for example:
device.addExampleListener(new BrickletDualRelay.ExampleListener() {
public void property(int value) {
System.out.println("Value: " + value);
}
});
The available listener classes with inherent methods to be overwritten
are described below. It is possible to add several listeners and
to remove them with the corresponding remove*Listener()
function.
Note
Using listeners for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.
BrickletDualRelay.
MonoflopDoneListener
()¶This listener can be added with the addMonoflopDoneListener()
function.
An added listener can be removed with the removeMonoflopDoneListener()
function.
monoflopDone
(short relay, boolean state)Parameters: |
|
---|
This listener is triggered whenever a monoflop timer reaches 0. The parameter contain the relay (1 or 2) and the current state of the relay (the state after the monoflop).
Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.
BrickletDualRelay.
getAPIVersion
()¶Return Object: |
|
---|
Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.
BrickletDualRelay.
getResponseExpected
(byte functionId)¶Parameters: |
|
---|---|
Returns: |
|
Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.
For getter functions this is enabled by default and cannot be disabled,
because those functions will always send a response. For listener configuration
functions it is enabled by default too, but can be disabled by
setResponseExpected()
. For setter functions it is disabled by default
and can be enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletDualRelay.
setResponseExpected
(byte functionId, boolean responseExpected)¶Parameters: |
|
---|
Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and listener configuration functions (default value: true). For getter functions it is always enabled.
Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.
The following constants are available for this function:
For functionId:
BrickletDualRelay.
setResponseExpectedAll
(boolean responseExpected)¶Parameters: |
|
---|
Changes the response expected flag for all setter and listener configuration functions of this device at once.
BrickletDualRelay.
DEVICE_IDENTIFIER
¶This constant is used to identify a Dual Relay Bricklet.
The getIdentity()
function and the
IPConnection.EnumerateListener
listener of the IP Connection have a deviceIdentifier
parameter to specify
the Brick's or Bricklet's type.
BrickletDualRelay.
DEVICE_DISPLAY_NAME