C/C++ - Voltage/Current Bricklet 2.0

This is the description of the C/C++ API bindings for the Voltage/Current Bricklet 2.0. General information and technical specifications for the Voltage/Current Bricklet 2.0 are summarized in its hardware description.

An installation guide for the C/C++ API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Callback

Download (example_callback.c)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
#include <stdio.h>

#include "ip_connection.h"
#include "bricklet_voltage_current_v2.h"

#define HOST "localhost"
#define PORT 4223
#define UID "XYZ" // Change XYZ to the UID of your Voltage/Current Bricklet 2.0

// Callback function for current callback
void cb_current(int32_t current, void *user_data) {
    (void)user_data; // avoid unused parameter warning

    printf("Current: %f A\n", current/1000.0);
}

int main(void) {
    // Create IP connection
    IPConnection ipcon;
    ipcon_create(&ipcon);

    // Create device object
    VoltageCurrentV2 vc;
    voltage_current_v2_create(&vc, UID, &ipcon);

    // Connect to brickd
    if(ipcon_connect(&ipcon, HOST, PORT) < 0) {
        fprintf(stderr, "Could not connect\n");
        return 1;
    }
    // Don't use device before ipcon is connected

    // Register current callback to function cb_current
    voltage_current_v2_register_callback(&vc,
                                         VOLTAGE_CURRENT_V2_CALLBACK_CURRENT,
                                         (void (*)(void))cb_current,
                                         NULL);

    // Set period for current callback to 1s (1000ms) without a threshold
    voltage_current_v2_set_current_callback_configuration(&vc, 1000, false, 'x', 0, 0);

    printf("Press key to exit\n");
    getchar();
    voltage_current_v2_destroy(&vc);
    ipcon_destroy(&ipcon); // Calls ipcon_disconnect internally
    return 0;
}

Threshold

Download (example_threshold.c)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
#include <stdio.h>

#include "ip_connection.h"
#include "bricklet_voltage_current_v2.h"

#define HOST "localhost"
#define PORT 4223
#define UID "XYZ" // Change XYZ to the UID of your Voltage/Current Bricklet 2.0

// Callback function for power callback
void cb_power(int32_t power, void *user_data) {
    (void)user_data; // avoid unused parameter warning

    printf("power: %f W\n", power/1000.0);
}

int main(void) {
    // Create IP connection
    IPConnection ipcon;
    ipcon_create(&ipcon);

    // Create device object
    VoltageCurrentV2 vc;
    voltage_current_v2_create(&vc, UID, &ipcon);

    // Connect to brickd
    if(ipcon_connect(&ipcon, HOST, PORT) < 0) {
        fprintf(stderr, "Could not connect\n");
        return 1;
    }
    // Don't use device before ipcon is connected

    // Register power callback to function cb_power
    voltage_current_v2_register_callback(&vc,
                                         VOLTAGE_CURRENT_V2_CALLBACK_POWER,
                                         (void (*)(void))cb_power,
                                         NULL);

    // Configure threshold for power "greater than 10 W"
    // with a debounce period of 1s (1000ms)
    voltage_current_v2_set_power_callback_configuration(&vc, 1000, false, '>', 10*1000, 0);

    printf("Press key to exit\n");
    getchar();
    voltage_current_v2_destroy(&vc);
    ipcon_destroy(&ipcon); // Calls ipcon_disconnect internally
    return 0;
}

Simple

Download (example_simple.c)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
#include <stdio.h>

#include "ip_connection.h"
#include "bricklet_voltage_current_v2.h"

#define HOST "localhost"
#define PORT 4223
#define UID "XYZ" // Change XYZ to the UID of your Voltage/Current Bricklet 2.0

int main(void) {
    // Create IP connection
    IPConnection ipcon;
    ipcon_create(&ipcon);

    // Create device object
    VoltageCurrentV2 vc;
    voltage_current_v2_create(&vc, UID, &ipcon);

    // Connect to brickd
    if(ipcon_connect(&ipcon, HOST, PORT) < 0) {
        fprintf(stderr, "Could not connect\n");
        return 1;
    }
    // Don't use device before ipcon is connected

    // Get current voltage
    int32_t voltage;
    if(voltage_current_v2_get_voltage(&vc, &voltage) < 0) {
        fprintf(stderr, "Could not get voltage, probably timeout\n");
        return 1;
    }

    printf("Voltage: %f V\n", voltage/1000.0);

    // Get current current
    int32_t current;
    if(voltage_current_v2_get_current(&vc, &current) < 0) {
        fprintf(stderr, "Could not get current, probably timeout\n");
        return 1;
    }

    printf("Current: %f A\n", current/1000.0);

    printf("Press key to exit\n");
    getchar();
    voltage_current_v2_destroy(&vc);
    ipcon_destroy(&ipcon); // Calls ipcon_disconnect internally
    return 0;
}

API

Most functions of the C/C++ bindings return an error code (e_code). Data returned from the device, when a getter is called, is handled via output parameters. These parameters are labeled with the ret_ prefix.

Possible error codes are:

  • E_OK = 0
  • E_TIMEOUT = -1
  • E_NO_STREAM_SOCKET = -2
  • E_HOSTNAME_INVALID = -3
  • E_NO_CONNECT = -4
  • E_NO_THREAD = -5
  • E_NOT_ADDED = -6 (unused since C/C++ bindings version 2.0.0)
  • E_ALREADY_CONNECTED = -7
  • E_NOT_CONNECTED = -8
  • E_INVALID_PARAMETER = -9
  • E_NOT_SUPPORTED = -10
  • E_UNKNOWN_ERROR_CODE = -11
  • E_STREAM_OUT_OF_SYNC = -12
  • E_INVALID_UID = -13
  • E_NON_ASCII_CHAR_IN_SECRET = -14
  • E_WRONG_DEVICE_TYPE = -15
  • E_DEVICE_REPLACED = -16
  • E_WRONG_RESPONSE_LENGTH = -17

as defined in ip_connection.h.

All functions listed below are thread-safe.

Basic Functions

void voltage_current_v2_create(VoltageCurrentV2 *voltage_current_v2, const char *uid, IPConnection *ipcon)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • uid – Type: const char *
  • ipcon – Type: IPConnection *

Creates the device object voltage_current_v2 with the unique device ID uid and adds it to the IPConnection ipcon:

VoltageCurrentV2 voltage_current_v2;
voltage_current_v2_create(&voltage_current_v2, "YOUR_DEVICE_UID", &ipcon);

This device object can be used after the IP connection has been connected.

void voltage_current_v2_destroy(VoltageCurrentV2 *voltage_current_v2)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *

Removes the device object voltage_current_v2 from its IPConnection and destroys it. The device object cannot be used anymore afterwards.

int voltage_current_v2_get_current(VoltageCurrentV2 *voltage_current_v2, int32_t *ret_current)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_current – Type: int32_t, Unit: 1 mA, Range: [-20000 to 20000]
Returns:
  • e_code – Type: int

Returns the current.

If you want to get the value periodically, it is recommended to use the VOLTAGE_CURRENT_V2_CALLBACK_CURRENT callback. You can set the callback configuration with voltage_current_v2_set_current_callback_configuration().

int voltage_current_v2_get_voltage(VoltageCurrentV2 *voltage_current_v2, int32_t *ret_voltage)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_voltage – Type: int32_t, Unit: 1 mV, Range: [0 to 36000]
Returns:
  • e_code – Type: int

Returns the voltage.

If you want to get the value periodically, it is recommended to use the VOLTAGE_CURRENT_V2_CALLBACK_VOLTAGE callback. You can set the callback configuration with voltage_current_v2_set_voltage_callback_configuration().

int voltage_current_v2_get_power(VoltageCurrentV2 *voltage_current_v2, int32_t *ret_power)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_power – Type: int32_t, Unit: 1 mW, Range: [0 to 720000]
Returns:
  • e_code – Type: int

Returns the power.

If you want to get the value periodically, it is recommended to use the VOLTAGE_CURRENT_V2_CALLBACK_POWER callback. You can set the callback configuration with voltage_current_v2_set_power_callback_configuration().

int voltage_current_v2_set_configuration(VoltageCurrentV2 *voltage_current_v2, uint8_t averaging, uint8_t voltage_conversion_time, uint8_t current_conversion_time)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • averaging – Type: uint8_t, Range: See constants, Default: 3
  • voltage_conversion_time – Type: uint8_t, Range: See constants, Default: 4
  • current_conversion_time – Type: uint8_t, Range: See constants, Default: 4
Returns:
  • e_code – Type: int

Sets the configuration of the Voltage/Current Bricklet 2.0. It is possible to configure number of averages as well as voltage and current conversion time.

The following constants are available for this function:

For averaging:

  • VOLTAGE_CURRENT_V2_AVERAGING_1 = 0
  • VOLTAGE_CURRENT_V2_AVERAGING_4 = 1
  • VOLTAGE_CURRENT_V2_AVERAGING_16 = 2
  • VOLTAGE_CURRENT_V2_AVERAGING_64 = 3
  • VOLTAGE_CURRENT_V2_AVERAGING_128 = 4
  • VOLTAGE_CURRENT_V2_AVERAGING_256 = 5
  • VOLTAGE_CURRENT_V2_AVERAGING_512 = 6
  • VOLTAGE_CURRENT_V2_AVERAGING_1024 = 7

For voltage_conversion_time:

  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_140US = 0
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_204US = 1
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_332US = 2
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_588US = 3
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_1_1MS = 4
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_2_116MS = 5
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_4_156MS = 6
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_8_244MS = 7

For current_conversion_time:

  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_140US = 0
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_204US = 1
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_332US = 2
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_588US = 3
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_1_1MS = 4
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_2_116MS = 5
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_4_156MS = 6
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_8_244MS = 7
int voltage_current_v2_get_configuration(VoltageCurrentV2 *voltage_current_v2, uint8_t *ret_averaging, uint8_t *ret_voltage_conversion_time, uint8_t *ret_current_conversion_time)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_averaging – Type: uint8_t, Range: See constants, Default: 3
  • ret_voltage_conversion_time – Type: uint8_t, Range: See constants, Default: 4
  • ret_current_conversion_time – Type: uint8_t, Range: See constants, Default: 4
Returns:
  • e_code – Type: int

Returns the configuration as set by voltage_current_v2_set_configuration().

The following constants are available for this function:

For ret_averaging:

  • VOLTAGE_CURRENT_V2_AVERAGING_1 = 0
  • VOLTAGE_CURRENT_V2_AVERAGING_4 = 1
  • VOLTAGE_CURRENT_V2_AVERAGING_16 = 2
  • VOLTAGE_CURRENT_V2_AVERAGING_64 = 3
  • VOLTAGE_CURRENT_V2_AVERAGING_128 = 4
  • VOLTAGE_CURRENT_V2_AVERAGING_256 = 5
  • VOLTAGE_CURRENT_V2_AVERAGING_512 = 6
  • VOLTAGE_CURRENT_V2_AVERAGING_1024 = 7

For ret_voltage_conversion_time:

  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_140US = 0
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_204US = 1
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_332US = 2
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_588US = 3
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_1_1MS = 4
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_2_116MS = 5
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_4_156MS = 6
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_8_244MS = 7

For ret_current_conversion_time:

  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_140US = 0
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_204US = 1
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_332US = 2
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_588US = 3
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_1_1MS = 4
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_2_116MS = 5
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_4_156MS = 6
  • VOLTAGE_CURRENT_V2_CONVERSION_TIME_8_244MS = 7

Advanced Functions

int voltage_current_v2_set_calibration(VoltageCurrentV2 *voltage_current_v2, uint16_t voltage_multiplier, uint16_t voltage_divisor, uint16_t current_multiplier, uint16_t current_divisor)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • voltage_multiplier – Type: uint16_t, Range: [0 to 216 - 1]
  • voltage_divisor – Type: uint16_t, Range: [0 to 216 - 1]
  • current_multiplier – Type: uint16_t, Range: [0 to 216 - 1]
  • current_divisor – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Since the ADC and the shunt resistor used for the measurements are not perfect they need to be calibrated by a multiplier and a divisor if a very precise reading is needed.

For example, if you are expecting a current of 1000mA and you are measuring 1023mA, you can calibrate the Voltage/Current Bricklet by setting the current multiplier to 1000 and the divisor to 1023. The same applies for the voltage.

The calibration will be saved on the EEPROM of the Voltage/Current Bricklet and only needs to be done once.

int voltage_current_v2_get_calibration(VoltageCurrentV2 *voltage_current_v2, uint16_t *ret_voltage_multiplier, uint16_t *ret_voltage_divisor, uint16_t *ret_current_multiplier, uint16_t *ret_current_divisor)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_voltage_multiplier – Type: uint16_t, Range: [0 to 216 - 1]
  • ret_voltage_divisor – Type: uint16_t, Range: [0 to 216 - 1]
  • ret_current_multiplier – Type: uint16_t, Range: [0 to 216 - 1]
  • ret_current_divisor – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Returns the calibration as set by voltage_current_v2_set_calibration().

int voltage_current_v2_get_spitfp_error_count(VoltageCurrentV2 *voltage_current_v2, uint32_t *ret_error_count_ack_checksum, uint32_t *ret_error_count_message_checksum, uint32_t *ret_error_count_frame, uint32_t *ret_error_count_overflow)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_error_count_ack_checksum – Type: uint32_t, Range: [0 to 232 - 1]
  • ret_error_count_message_checksum – Type: uint32_t, Range: [0 to 232 - 1]
  • ret_error_count_frame – Type: uint32_t, Range: [0 to 232 - 1]
  • ret_error_count_overflow – Type: uint32_t, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

int voltage_current_v2_set_status_led_config(VoltageCurrentV2 *voltage_current_v2, uint8_t config)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • config – Type: uint8_t, Range: See constants, Default: 3
Returns:
  • e_code – Type: int

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following constants are available for this function:

For config:

  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_OFF = 0
  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_ON = 1
  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_SHOW_STATUS = 3
int voltage_current_v2_get_status_led_config(VoltageCurrentV2 *voltage_current_v2, uint8_t *ret_config)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_config – Type: uint8_t, Range: See constants, Default: 3
Returns:
  • e_code – Type: int

Returns the configuration as set by voltage_current_v2_set_status_led_config()

The following constants are available for this function:

For ret_config:

  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_OFF = 0
  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_ON = 1
  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • VOLTAGE_CURRENT_V2_STATUS_LED_CONFIG_SHOW_STATUS = 3
int voltage_current_v2_get_chip_temperature(VoltageCurrentV2 *voltage_current_v2, int16_t *ret_temperature)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_temperature – Type: int16_t, Unit: 1 °C, Range: [-215 to 215 - 1]
Returns:
  • e_code – Type: int

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

int voltage_current_v2_reset(VoltageCurrentV2 *voltage_current_v2)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Returns:
  • e_code – Type: int

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

int voltage_current_v2_get_identity(VoltageCurrentV2 *voltage_current_v2, char ret_uid[8], char ret_connected_uid[8], char *ret_position, uint8_t ret_hardware_version[3], uint8_t ret_firmware_version[3], uint16_t *ret_device_identifier)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_uid – Type: char[8]
  • ret_connected_uid – Type: char[8]
  • ret_position – Type: char, Range: ['a' to 'h', 'z']
  • ret_hardware_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
  • ret_firmware_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
  • ret_device_identifier – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Callback Configuration Functions

void voltage_current_v2_register_callback(VoltageCurrentV2 *voltage_current_v2, int16_t callback_id, void (*function)(void), void *user_data)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • callback_id – Type: int16_t
  • function – Type: void (*)(void)
  • user_data – Type: void *

Registers the given function with the given callback_id. The user_data will be passed as the last parameter to the function.

The available callback IDs with corresponding function signatures are listed below.

int voltage_current_v2_set_current_callback_configuration(VoltageCurrentV2 *voltage_current_v2, uint32_t period, bool value_has_to_change, char option, int32_t min, int32_t max)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • period – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int32_t, Unit: 1 mA, Range: [-231 to 231 - 1], Default: 0
  • max – Type: int32_t, Unit: 1 mA, Range: [-231 to 231 - 1], Default: 0
Returns:
  • e_code – Type: int

The period is the period with which the VOLTAGE_CURRENT_V2_CALLBACK_CURRENT callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the VOLTAGE_CURRENT_V2_CALLBACK_CURRENT callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following constants are available for this function:

For option:

  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OFF = 'x'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OUTSIDE = 'o'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_INSIDE = 'i'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_SMALLER = '<'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_GREATER = '>'
int voltage_current_v2_get_current_callback_configuration(VoltageCurrentV2 *voltage_current_v2, uint32_t *ret_period, bool *ret_value_has_to_change, char *ret_option, int32_t *ret_min, int32_t *ret_max)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_period – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • ret_value_has_to_change – Type: bool, Default: false
  • ret_option – Type: char, Range: See constants, Default: 'x'
  • ret_min – Type: int32_t, Unit: 1 mA, Range: [-231 to 231 - 1], Default: 0
  • ret_max – Type: int32_t, Unit: 1 mA, Range: [-231 to 231 - 1], Default: 0
Returns:
  • e_code – Type: int

Returns the callback configuration as set by voltage_current_v2_set_current_callback_configuration().

The following constants are available for this function:

For ret_option:

  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OFF = 'x'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OUTSIDE = 'o'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_INSIDE = 'i'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_SMALLER = '<'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_GREATER = '>'
int voltage_current_v2_set_voltage_callback_configuration(VoltageCurrentV2 *voltage_current_v2, uint32_t period, bool value_has_to_change, char option, int32_t min, int32_t max)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • period – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int32_t, Unit: 1 mV, Range: [-231 to 231 - 1], Default: 0
  • max – Type: int32_t, Unit: 1 mV, Range: [-231 to 231 - 1], Default: 0
Returns:
  • e_code – Type: int

The period is the period with which the VOLTAGE_CURRENT_V2_CALLBACK_VOLTAGE callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the VOLTAGE_CURRENT_V2_CALLBACK_VOLTAGE callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following constants are available for this function:

For option:

  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OFF = 'x'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OUTSIDE = 'o'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_INSIDE = 'i'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_SMALLER = '<'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_GREATER = '>'
int voltage_current_v2_get_voltage_callback_configuration(VoltageCurrentV2 *voltage_current_v2, uint32_t *ret_period, bool *ret_value_has_to_change, char *ret_option, int32_t *ret_min, int32_t *ret_max)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_period – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • ret_value_has_to_change – Type: bool, Default: false
  • ret_option – Type: char, Range: See constants, Default: 'x'
  • ret_min – Type: int32_t, Unit: 1 mV, Range: [-231 to 231 - 1], Default: 0
  • ret_max – Type: int32_t, Unit: 1 mV, Range: [-231 to 231 - 1], Default: 0
Returns:
  • e_code – Type: int

Returns the callback configuration as set by voltage_current_v2_set_voltage_callback_configuration().

The following constants are available for this function:

For ret_option:

  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OFF = 'x'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OUTSIDE = 'o'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_INSIDE = 'i'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_SMALLER = '<'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_GREATER = '>'
int voltage_current_v2_set_power_callback_configuration(VoltageCurrentV2 *voltage_current_v2, uint32_t period, bool value_has_to_change, char option, int32_t min, int32_t max)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • period – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • value_has_to_change – Type: bool, Default: false
  • option – Type: char, Range: See constants, Default: 'x'
  • min – Type: int32_t, Unit: 1 mW, Range: [-231 to 231 - 1], Default: 0
  • max – Type: int32_t, Unit: 1 mW, Range: [-231 to 231 - 1], Default: 0
Returns:
  • e_code – Type: int

The period is the period with which the VOLTAGE_CURRENT_V2_CALLBACK_POWER callback is triggered periodically. A value of 0 turns the callback off.

If the value has to change-parameter is set to true, the callback is only triggered after the value has changed. If the value didn't change within the period, the callback is triggered immediately on change.

If it is set to false, the callback is continuously triggered with the period, independent of the value.

It is furthermore possible to constrain the callback with thresholds.

The option-parameter together with min/max sets a threshold for the VOLTAGE_CURRENT_V2_CALLBACK_POWER callback.

The following options are possible:

Option Description
'x' Threshold is turned off
'o' Threshold is triggered when the value is outside the min and max values
'i' Threshold is triggered when the value is inside or equal to the min and max values
'<' Threshold is triggered when the value is smaller than the min value (max is ignored)
'>' Threshold is triggered when the value is greater than the min value (max is ignored)

If the option is set to 'x' (threshold turned off) the callback is triggered with the fixed period.

The following constants are available for this function:

For option:

  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OFF = 'x'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OUTSIDE = 'o'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_INSIDE = 'i'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_SMALLER = '<'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_GREATER = '>'
int voltage_current_v2_get_power_callback_configuration(VoltageCurrentV2 *voltage_current_v2, uint32_t *ret_period, bool *ret_value_has_to_change, char *ret_option, int32_t *ret_min, int32_t *ret_max)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_period – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1], Default: 0
  • ret_value_has_to_change – Type: bool, Default: false
  • ret_option – Type: char, Range: See constants, Default: 'x'
  • ret_min – Type: int32_t, Unit: 1 mW, Range: [-231 to 231 - 1], Default: 0
  • ret_max – Type: int32_t, Unit: 1 mW, Range: [-231 to 231 - 1], Default: 0
Returns:
  • e_code – Type: int

Returns the callback configuration as set by voltage_current_v2_set_power_callback_configuration().

The following constants are available for this function:

For ret_option:

  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OFF = 'x'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_OUTSIDE = 'o'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_INSIDE = 'i'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_SMALLER = '<'
  • VOLTAGE_CURRENT_V2_THRESHOLD_OPTION_GREATER = '>'

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done with the voltage_current_v2_register_callback() function:

void my_callback(int value, void *user_data) {
    printf("Value: %d\n", value);
}

voltage_current_v2_register_callback(&voltage_current_v2,
                                     VOLTAGE_CURRENT_V2_CALLBACK_EXAMPLE,
                                     (void (*)(void))my_callback,
                                     NULL);

The available constants with corresponding function signatures are described below.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

VOLTAGE_CURRENT_V2_CALLBACK_CURRENT
void callback(int32_t current, void *user_data)
Callback Parameters:
  • current – Type: int32_t, Unit: 1 mA, Range: [-20000 to 20000]
  • user_data – Type: void *

This callback is triggered periodically according to the configuration set by voltage_current_v2_set_current_callback_configuration().

The parameter is the same as voltage_current_v2_get_current().

VOLTAGE_CURRENT_V2_CALLBACK_VOLTAGE
void callback(int32_t voltage, void *user_data)
Callback Parameters:
  • voltage – Type: int32_t, Unit: 1 mV, Range: [0 to 36000]
  • user_data – Type: void *

This callback is triggered periodically according to the configuration set by voltage_current_v2_set_voltage_callback_configuration().

The parameter is the same as voltage_current_v2_get_voltage().

VOLTAGE_CURRENT_V2_CALLBACK_POWER
void callback(int32_t power, void *user_data)
Callback Parameters:
  • power – Type: int32_t, Unit: 1 mW, Range: [0 to 720000]
  • user_data – Type: void *

This callback is triggered periodically according to the configuration set by voltage_current_v2_set_power_callback_configuration().

The parameter is the same as voltage_current_v2_get_power().

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

int voltage_current_v2_get_api_version(VoltageCurrentV2 *voltage_current_v2, uint8_t ret_api_version[3])
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_api_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
Returns:
  • e_code – Type: int

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

int voltage_current_v2_get_response_expected(VoltageCurrentV2 *voltage_current_v2, uint8_t function_id, bool *ret_response_expected)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • function_id – Type: uint8_t, Range: See constants
Output Parameters:
  • ret_response_expected – Type: bool
Returns:
  • e_code – Type: int

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by voltage_current_v2_set_response_expected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • VOLTAGE_CURRENT_V2_FUNCTION_SET_CURRENT_CALLBACK_CONFIGURATION = 2
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_VOLTAGE_CALLBACK_CONFIGURATION = 6
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_POWER_CALLBACK_CONFIGURATION = 10
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_CONFIGURATION = 13
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_CALIBRATION = 15
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_STATUS_LED_CONFIG = 239
  • VOLTAGE_CURRENT_V2_FUNCTION_RESET = 243
  • VOLTAGE_CURRENT_V2_FUNCTION_WRITE_UID = 248
int voltage_current_v2_set_response_expected(VoltageCurrentV2 *voltage_current_v2, uint8_t function_id, bool response_expected)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • function_id – Type: uint8_t, Range: See constants
  • response_expected – Type: bool
Returns:
  • e_code – Type: int

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • VOLTAGE_CURRENT_V2_FUNCTION_SET_CURRENT_CALLBACK_CONFIGURATION = 2
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_VOLTAGE_CALLBACK_CONFIGURATION = 6
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_POWER_CALLBACK_CONFIGURATION = 10
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_CONFIGURATION = 13
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_CALIBRATION = 15
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • VOLTAGE_CURRENT_V2_FUNCTION_SET_STATUS_LED_CONFIG = 239
  • VOLTAGE_CURRENT_V2_FUNCTION_RESET = 243
  • VOLTAGE_CURRENT_V2_FUNCTION_WRITE_UID = 248
int voltage_current_v2_set_response_expected_all(VoltageCurrentV2 *voltage_current_v2, bool response_expected)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • response_expected – Type: bool
Returns:
  • e_code – Type: int

Changes the response expected flag for all setter and callback configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

int voltage_current_v2_set_bootloader_mode(VoltageCurrentV2 *voltage_current_v2, uint8_t mode, uint8_t *ret_status)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • mode – Type: uint8_t, Range: See constants
Output Parameters:
  • ret_status – Type: uint8_t, Range: See constants
Returns:
  • e_code – Type: int

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following constants are available for this function:

For mode:

  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_BOOTLOADER = 0
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_FIRMWARE = 1
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4

For ret_status:

  • VOLTAGE_CURRENT_V2_BOOTLOADER_STATUS_OK = 0
  • VOLTAGE_CURRENT_V2_BOOTLOADER_STATUS_INVALID_MODE = 1
  • VOLTAGE_CURRENT_V2_BOOTLOADER_STATUS_NO_CHANGE = 2
  • VOLTAGE_CURRENT_V2_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT = 3
  • VOLTAGE_CURRENT_V2_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT = 4
  • VOLTAGE_CURRENT_V2_BOOTLOADER_STATUS_CRC_MISMATCH = 5
int voltage_current_v2_get_bootloader_mode(VoltageCurrentV2 *voltage_current_v2, uint8_t *ret_mode)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_mode – Type: uint8_t, Range: See constants
Returns:
  • e_code – Type: int

Returns the current bootloader mode, see voltage_current_v2_set_bootloader_mode().

The following constants are available for this function:

For ret_mode:

  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_BOOTLOADER = 0
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_FIRMWARE = 1
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • VOLTAGE_CURRENT_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4
int voltage_current_v2_set_write_firmware_pointer(VoltageCurrentV2 *voltage_current_v2, uint32_t pointer)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • pointer – Type: uint32_t, Unit: 1 B, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Sets the firmware pointer for voltage_current_v2_write_firmware(). The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

int voltage_current_v2_write_firmware(VoltageCurrentV2 *voltage_current_v2, uint8_t data[64], uint8_t *ret_status)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • data – Type: uint8_t[64], Range: [0 to 255]
Output Parameters:
  • ret_status – Type: uint8_t, Range: [0 to 255]
Returns:
  • e_code – Type: int

Writes 64 Bytes of firmware at the position as written by voltage_current_v2_set_write_firmware_pointer() before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

int voltage_current_v2_write_uid(VoltageCurrentV2 *voltage_current_v2, uint32_t uid)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
  • uid – Type: uint32_t, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

int voltage_current_v2_read_uid(VoltageCurrentV2 *voltage_current_v2, uint32_t *ret_uid)
Parameters:
  • voltage_current_v2 – Type: VoltageCurrentV2 *
Output Parameters:
  • ret_uid – Type: uint32_t, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Constants

VOLTAGE_CURRENT_V2_DEVICE_IDENTIFIER

This constant is used to identify a Voltage/Current Bricklet 2.0.

The voltage_current_v2_get_identity() function and the IPCON_CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

VOLTAGE_CURRENT_V2_DEVICE_DISPLAY_NAME

This constant represents the human readable name of a Voltage/Current Bricklet 2.0.