C/C++ - Industrial Digital Out 4 Bricklet 2.0

This is the description of the C/C++ API bindings for the Industrial Digital Out 4 Bricklet 2.0. General information and technical specifications for the Industrial Digital Out 4 Bricklet 2.0 are summarized in its hardware description.

An installation guide for the C/C++ API bindings is part of their general description.

Examples

The example code below is Public Domain (CC0 1.0).

Simple

Download (example_simple.c)

 1
 2
 3
 4
 5
 6
 7
 8
 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
#define IPCON_EXPOSE_MILLISLEEP

#include <stdio.h>

#include "ip_connection.h"
#include "bricklet_industrial_digital_out_4_v2.h"

#define HOST "localhost"
#define PORT 4223
#define UID "XYZ" // Change XYZ to the UID of your Industrial Digital Out 4 Bricklet 2.0

int main(void) {
    // Create IP connection
    IPConnection ipcon;
    ipcon_create(&ipcon);

    // Create device object
    IndustrialDigitalOut4V2 ido4;
    industrial_digital_out_4_v2_create(&ido4, UID, &ipcon);

    // Connect to brickd
    if(ipcon_connect(&ipcon, HOST, PORT) < 0) {
        fprintf(stderr, "Could not connect\n");
        return 1;
    }
    // Don't use device before ipcon is connected

    // Set channels alternating high/low 10 times with 100 ms delay
    int i;
    for(i = 0; i < 10; ++i) {
        millisleep(100);
        bool value[4] = {true, false, false, false};
        industrial_digital_out_4_v2_set_value(&ido4, value);
        millisleep(100);
        bool value_1[4] = {false, true, false, false};
        industrial_digital_out_4_v2_set_value(&ido4, value_1);
        millisleep(100);
        bool value_2[4] = {false, false, true, false};
        industrial_digital_out_4_v2_set_value(&ido4, value_2);
        millisleep(100);
        bool value_3[4] = {false, false, false, true};
        industrial_digital_out_4_v2_set_value(&ido4, value_3);
    }

    printf("Press key to exit\n");
    getchar();
    industrial_digital_out_4_v2_destroy(&ido4);
    ipcon_destroy(&ipcon); // Calls ipcon_disconnect internally
    return 0;
}

API

Most functions of the C/C++ bindings return an error code (e_code). Data returned from the device, when a getter is called, is handled via output parameters. These parameters are labeled with the ret_ prefix.

Possible error codes are:

  • E_OK = 0
  • E_TIMEOUT = -1
  • E_NO_STREAM_SOCKET = -2
  • E_HOSTNAME_INVALID = -3
  • E_NO_CONNECT = -4
  • E_NO_THREAD = -5
  • E_NOT_ADDED = -6 (unused since C/C++ bindings version 2.0.0)
  • E_ALREADY_CONNECTED = -7
  • E_NOT_CONNECTED = -8
  • E_INVALID_PARAMETER = -9
  • E_NOT_SUPPORTED = -10
  • E_UNKNOWN_ERROR_CODE = -11
  • E_STREAM_OUT_OF_SYNC = -12
  • E_INVALID_UID = -13
  • E_NON_ASCII_CHAR_IN_SECRET = -14
  • E_WRONG_DEVICE_TYPE = -15
  • E_DEVICE_REPLACED = -16
  • E_WRONG_RESPONSE_LENGTH = -17

as defined in ip_connection.h.

All functions listed below are thread-safe.

Basic Functions

void industrial_digital_out_4_v2_create(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, const char *uid, IPConnection *ipcon)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • uid – Type: const char *
  • ipcon – Type: IPConnection *

Creates the device object industrial_digital_out_4_v2 with the unique device ID uid and adds it to the IPConnection ipcon:

IndustrialDigitalOut4V2 industrial_digital_out_4_v2;
industrial_digital_out_4_v2_create(&industrial_digital_out_4_v2, "YOUR_DEVICE_UID", &ipcon);

This device object can be used after the IP connection has been connected.

void industrial_digital_out_4_v2_destroy(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *

Removes the device object industrial_digital_out_4_v2 from its IPConnection and destroys it. The device object cannot be used anymore afterwards.

int industrial_digital_out_4_v2_set_value(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, bool value[4])
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • value – Type: bool[4]
Returns:
  • e_code – Type: int

Sets the output value of all four channels. A value of true or false outputs logic 1 or logic 0 respectively on the corresponding channel.

Use industrial_digital_out_4_v2_set_selected_value() to change only one output channel state.

All running monoflop timers and PWMs will be aborted if this function is called.

For example: (True, True, False, False) will turn the channels 0-1 high and the channels 2-3 low.

int industrial_digital_out_4_v2_get_value(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, bool ret_value[4])
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_value – Type: bool[4]
Returns:
  • e_code – Type: int

Returns the logic levels that are currently output on the channels.

int industrial_digital_out_4_v2_set_selected_value(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, bool value)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
  • value – Type: bool
Returns:
  • e_code – Type: int

Sets the output value of a specific channel without affecting the other channels.

A running monoflop timer or PWM for the specified channel will be aborted if this function is called.

int industrial_digital_out_4_v2_set_channel_led_config(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, uint8_t config)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
  • config – Type: uint8_t, Range: See constants, Default: 3
Returns:
  • e_code – Type: int

Each channel has a corresponding LED. You can turn the LED off, on or show a heartbeat. You can also set the LED to "Channel Status". In this mode the LED is on if the channel is high and off otherwise.

By default all channel LEDs are configured as "Channel Status".

The following constants are available for this function:

For config:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_OFF = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_ON = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_SHOW_HEARTBEAT = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_SHOW_CHANNEL_STATUS = 3
int industrial_digital_out_4_v2_get_channel_led_config(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, uint8_t *ret_config)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
Output Parameters:
  • ret_config – Type: uint8_t, Range: See constants, Default: 3
Returns:
  • e_code – Type: int

Returns the channel LED configuration as set by industrial_digital_out_4_v2_set_channel_led_config()

The following constants are available for this function:

For ret_config:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_OFF = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_ON = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_SHOW_HEARTBEAT = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_CHANNEL_LED_CONFIG_SHOW_CHANNEL_STATUS = 3

Advanced Functions

int industrial_digital_out_4_v2_set_monoflop(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, bool value, uint32_t time)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
  • value – Type: bool
  • time – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

The first parameter is the desired state of the channel (true means output high and false means output low). The second parameter indicates the time that the channel should hold the state.

If this function is called with the parameters (true, 1500): The channel will turn on and in 1.5s it will turn off again.

A PWM for the selected channel will be aborted if this function is called.

A monoflop can be used as a failsafe mechanism. For example: Lets assume you have a RS485 bus and a IO-4 Bricklet is connected to one of the slave stacks. You can now call this function every second, with a time parameter of two seconds. The channel will be high all the time. If now the RS485 connection is lost, the channel will turn low in at most two seconds.

int industrial_digital_out_4_v2_get_monoflop(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, bool *ret_value, uint32_t *ret_time, uint32_t *ret_time_remaining)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
Output Parameters:
  • ret_value – Type: bool
  • ret_time – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1]
  • ret_time_remaining – Type: uint32_t, Unit: 1 ms, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Returns (for the given channel) the current value and the time as set by industrial_digital_out_4_v2_set_monoflop() as well as the remaining time until the value flips.

If the timer is not running currently, the remaining time will be returned as 0.

int industrial_digital_out_4_v2_set_pwm_configuration(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, uint32_t frequency, uint16_t duty_cycle)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
  • frequency – Type: uint32_t, Unit: 1/10 Hz, Range: [0 to 232 - 1], Default: 0
  • duty_cycle – Type: uint16_t, Unit: 1/100 %, Range: [0 to 10000], Default: 0
Returns:
  • e_code – Type: int

Activates a PWM for the given channel.

To turn the PWM off again, you can set the frequency to 0 or any other function that changes a value of the channel (e.g. industrial_digital_out_4_v2_set_selected_value()).

The optocoupler of the Industrial Digital Out 4 Bricklet 2.0 has a rise time and fall time of 11.5us (each) at 24V. So the maximum useful frequency value is about 400000 (40kHz).

A running monoflop timer for the given channel will be aborted if this function is called.

int industrial_digital_out_4_v2_get_pwm_configuration(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t channel, uint32_t *ret_frequency, uint16_t *ret_duty_cycle)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • channel – Type: uint8_t, Range: [0 to 3]
Output Parameters:
  • ret_frequency – Type: uint32_t, Unit: 1/10 Hz, Range: [0 to 232 - 1], Default: 0
  • ret_duty_cycle – Type: uint16_t, Unit: 1/100 %, Range: [0 to 10000], Default: 0
Returns:
  • e_code – Type: int

Returns the PWM configuration as set by industrial_digital_out_4_v2_set_pwm_configuration().

int industrial_digital_out_4_v2_get_spitfp_error_count(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint32_t *ret_error_count_ack_checksum, uint32_t *ret_error_count_message_checksum, uint32_t *ret_error_count_frame, uint32_t *ret_error_count_overflow)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_error_count_ack_checksum – Type: uint32_t, Range: [0 to 232 - 1]
  • ret_error_count_message_checksum – Type: uint32_t, Range: [0 to 232 - 1]
  • ret_error_count_frame – Type: uint32_t, Range: [0 to 232 - 1]
  • ret_error_count_overflow – Type: uint32_t, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Returns the error count for the communication between Brick and Bricklet.

The errors are divided into

  • ACK checksum errors,
  • message checksum errors,
  • framing errors and
  • overflow errors.

The errors counts are for errors that occur on the Bricklet side. All Bricks have a similar function that returns the errors on the Brick side.

int industrial_digital_out_4_v2_set_status_led_config(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t config)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • config – Type: uint8_t, Range: See constants, Default: 3
Returns:
  • e_code – Type: int

Sets the status LED configuration. By default the LED shows communication traffic between Brick and Bricklet, it flickers once for every 10 received data packets.

You can also turn the LED permanently on/off or show a heartbeat.

If the Bricklet is in bootloader mode, the LED is will show heartbeat by default.

The following constants are available for this function:

For config:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_OFF = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_ON = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_SHOW_STATUS = 3
int industrial_digital_out_4_v2_get_status_led_config(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t *ret_config)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_config – Type: uint8_t, Range: See constants, Default: 3
Returns:
  • e_code – Type: int

Returns the configuration as set by industrial_digital_out_4_v2_set_status_led_config()

The following constants are available for this function:

For ret_config:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_OFF = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_ON = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_SHOW_HEARTBEAT = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_STATUS_LED_CONFIG_SHOW_STATUS = 3
int industrial_digital_out_4_v2_get_chip_temperature(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, int16_t *ret_temperature)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_temperature – Type: int16_t, Unit: 1 °C, Range: [-215 to 215 - 1]
Returns:
  • e_code – Type: int

Returns the temperature as measured inside the microcontroller. The value returned is not the ambient temperature!

The temperature is only proportional to the real temperature and it has bad accuracy. Practically it is only useful as an indicator for temperature changes.

int industrial_digital_out_4_v2_reset(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Returns:
  • e_code – Type: int

Calling this function will reset the Bricklet. All configurations will be lost.

After a reset you have to create new device objects, calling functions on the existing ones will result in undefined behavior!

int industrial_digital_out_4_v2_get_identity(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, char ret_uid[8], char ret_connected_uid[8], char *ret_position, uint8_t ret_hardware_version[3], uint8_t ret_firmware_version[3], uint16_t *ret_device_identifier)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_uid – Type: char[8]
  • ret_connected_uid – Type: char[8]
  • ret_position – Type: char, Range: ['a' to 'h', 'z']
  • ret_hardware_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
  • ret_firmware_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
  • ret_device_identifier – Type: uint16_t, Range: [0 to 216 - 1]
Returns:
  • e_code – Type: int

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an Isolator Bricklet is always at position 'z'.

The device identifier numbers can be found here. There is also a constant for the device identifier of this Bricklet.

Callback Configuration Functions

void industrial_digital_out_4_v2_register_callback(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, int16_t callback_id, void (*function)(void), void *user_data)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • callback_id – Type: int16_t
  • function – Type: void (*)(void)
  • user_data – Type: void *

Registers the given function with the given callback_id. The user_data will be passed as the last parameter to the function.

The available callback IDs with corresponding function signatures are listed below.

Callbacks

Callbacks can be registered to receive time critical or recurring data from the device. The registration is done with the industrial_digital_out_4_v2_register_callback() function:

void my_callback(int value, void *user_data) {
    printf("Value: %d\n", value);
}

industrial_digital_out_4_v2_register_callback(&industrial_digital_out_4_v2,
                                              INDUSTRIAL_DIGITAL_OUT_4_V2_CALLBACK_EXAMPLE,
                                              (void (*)(void))my_callback,
                                              NULL);

The available constants with corresponding function signatures are described below.

Note

Using callbacks for recurring events is always preferred compared to using getters. It will use less USB bandwidth and the latency will be a lot better, since there is no round trip time.

INDUSTRIAL_DIGITAL_OUT_4_V2_CALLBACK_MONOFLOP_DONE
void callback(uint8_t channel, bool value, void *user_data)
Callback Parameters:
  • channel – Type: uint8_t, Range: [0 to 3]
  • value – Type: bool
  • user_data – Type: void *

This callback is triggered whenever a monoflop timer reaches 0. The parameters contain the channel and the current value of the channel (the value after the monoflop).

Virtual Functions

Virtual functions don't communicate with the device itself, but operate only on the API bindings device object. They can be called without the corresponding IP Connection object being connected.

int industrial_digital_out_4_v2_get_api_version(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t ret_api_version[3])
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_api_version – Type: uint8_t[3]
    • 0: major – Type: uint8_t, Range: [0 to 255]
    • 1: minor – Type: uint8_t, Range: [0 to 255]
    • 2: revision – Type: uint8_t, Range: [0 to 255]
Returns:
  • e_code – Type: int

Returns the version of the API definition implemented by this API bindings. This is neither the release version of this API bindings nor does it tell you anything about the represented Brick or Bricklet.

int industrial_digital_out_4_v2_get_response_expected(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t function_id, bool *ret_response_expected)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • function_id – Type: uint8_t, Range: See constants
Output Parameters:
  • ret_response_expected – Type: bool
Returns:
  • e_code – Type: int

Returns the response expected flag for the function specified by the function ID parameter. It is true if the function is expected to send a response, false otherwise.

For getter functions this is enabled by default and cannot be disabled, because those functions will always send a response. For callback configuration functions it is enabled by default too, but can be disabled by industrial_digital_out_4_v2_set_response_expected(). For setter functions it is disabled by default and can be enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_VALUE = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_SELECTED_VALUE = 3
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_MONOFLOP = 4
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_CHANNEL_LED_CONFIG = 7
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_PWM_CONFIGURATION = 9
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_STATUS_LED_CONFIG = 239
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_RESET = 243
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_WRITE_UID = 248
int industrial_digital_out_4_v2_set_response_expected(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t function_id, bool response_expected)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • function_id – Type: uint8_t, Range: See constants
  • response_expected – Type: bool
Returns:
  • e_code – Type: int

Changes the response expected flag of the function specified by the function ID parameter. This flag can only be changed for setter (default value: false) and callback configuration functions (default value: true). For getter functions it is always enabled.

Enabling the response expected flag for a setter function allows to detect timeouts and other error conditions calls of this setter as well. The device will then send a response for this purpose. If this flag is disabled for a setter function then no response is sent and errors are silently ignored, because they cannot be detected.

The following constants are available for this function:

For function_id:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_VALUE = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_SELECTED_VALUE = 3
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_MONOFLOP = 4
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_CHANNEL_LED_CONFIG = 7
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_PWM_CONFIGURATION = 9
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_WRITE_FIRMWARE_POINTER = 237
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_SET_STATUS_LED_CONFIG = 239
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_RESET = 243
  • INDUSTRIAL_DIGITAL_OUT_4_V2_FUNCTION_WRITE_UID = 248
int industrial_digital_out_4_v2_set_response_expected_all(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, bool response_expected)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • response_expected – Type: bool
Returns:
  • e_code – Type: int

Changes the response expected flag for all setter and callback configuration functions of this device at once.

Internal Functions

Internal functions are used for maintenance tasks such as flashing a new firmware of changing the UID of a Bricklet. These task should be performed using Brick Viewer instead of using the internal functions directly.

int industrial_digital_out_4_v2_set_bootloader_mode(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t mode, uint8_t *ret_status)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • mode – Type: uint8_t, Range: See constants
Output Parameters:
  • ret_status – Type: uint8_t, Range: See constants
Returns:
  • e_code – Type: int

Sets the bootloader mode and returns the status after the requested mode change was instigated.

You can change from bootloader mode to firmware mode and vice versa. A change from bootloader mode to firmware mode will only take place if the entry function, device identifier and CRC are present and correct.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

The following constants are available for this function:

For mode:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_BOOTLOADER = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_FIRMWARE = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4

For ret_status:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_STATUS_OK = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_STATUS_INVALID_MODE = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_STATUS_NO_CHANGE = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_STATUS_ENTRY_FUNCTION_NOT_PRESENT = 3
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_STATUS_DEVICE_IDENTIFIER_INCORRECT = 4
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_STATUS_CRC_MISMATCH = 5
int industrial_digital_out_4_v2_get_bootloader_mode(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t *ret_mode)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_mode – Type: uint8_t, Range: See constants
Returns:
  • e_code – Type: int

Returns the current bootloader mode, see industrial_digital_out_4_v2_set_bootloader_mode().

The following constants are available for this function:

For ret_mode:

  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_BOOTLOADER = 0
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_FIRMWARE = 1
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_BOOTLOADER_WAIT_FOR_REBOOT = 2
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_REBOOT = 3
  • INDUSTRIAL_DIGITAL_OUT_4_V2_BOOTLOADER_MODE_FIRMWARE_WAIT_FOR_ERASE_AND_REBOOT = 4
int industrial_digital_out_4_v2_set_write_firmware_pointer(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint32_t pointer)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • pointer – Type: uint32_t, Unit: 1 B, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Sets the firmware pointer for industrial_digital_out_4_v2_write_firmware(). The pointer has to be increased by chunks of size 64. The data is written to flash every 4 chunks (which equals to one page of size 256).

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

int industrial_digital_out_4_v2_write_firmware(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint8_t data[64], uint8_t *ret_status)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • data – Type: uint8_t[64], Range: [0 to 255]
Output Parameters:
  • ret_status – Type: uint8_t, Range: [0 to 255]
Returns:
  • e_code – Type: int

Writes 64 Bytes of firmware at the position as written by industrial_digital_out_4_v2_set_write_firmware_pointer() before. The firmware is written to flash every 4 chunks.

You can only write firmware in bootloader mode.

This function is used by Brick Viewer during flashing. It should not be necessary to call it in a normal user program.

int industrial_digital_out_4_v2_write_uid(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint32_t uid)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
  • uid – Type: uint32_t, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Writes a new UID into flash. If you want to set a new UID you have to decode the Base58 encoded UID string into an integer first.

We recommend that you use Brick Viewer to change the UID.

int industrial_digital_out_4_v2_read_uid(IndustrialDigitalOut4V2 *industrial_digital_out_4_v2, uint32_t *ret_uid)
Parameters:
  • industrial_digital_out_4_v2 – Type: IndustrialDigitalOut4V2 *
Output Parameters:
  • ret_uid – Type: uint32_t, Range: [0 to 232 - 1]
Returns:
  • e_code – Type: int

Returns the current UID as an integer. Encode as Base58 to get the usual string version.

Constants

INDUSTRIAL_DIGITAL_OUT_4_V2_DEVICE_IDENTIFIER

This constant is used to identify a Industrial Digital Out 4 Bricklet 2.0.

The industrial_digital_out_4_v2_get_identity() function and the IPCON_CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

INDUSTRIAL_DIGITAL_OUT_4_V2_DEVICE_DISPLAY_NAME

This constant represents the human readable name of a Industrial Digital Out 4 Bricklet 2.0.